Steinbach FXS38 handleiding

15 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 12 van 15
22 23
040603_V2405 040603_V2405
Installaon
Some hoses are very s. Place them in the sun before installaon so that they become more exible
due to the heat.
Integrate the device into the water circuit
Observe the layout diagram according to Figure B.
» Connect the hoses for the water supply and drainage to the appliance.
» Recommended addional material: Swimming pool hoses Ø 32 mm and hose clamps as required.
Connecon to Ø 38 mm installaon:
The appliance can be connected to a Ø 38 mm hose using the double hose nozzle (060034) and hose clamps
(060038).
Connecon to INTEX hose with 2“ union nut:
With a 2“ double nipple (062085), at gasket (0409331) and the adapter A - 2“ female thread / Ø 32/38 mm
(110849), the device can be connected to an INTEX hose with a 2“ union nut.
You can nd suitable adapters in our webshop at: www.steinbach-group.com
Proceed as follows to connect a swimming
pool hose to the pump or lter vessel:
1. Guide a hose clamp over the hose.
2. Push the hose onto the hose connecon.
3. Secure the hose clip to the hose connecon
using a PH1 Phillips screwdriver.
The plugged swimming pool hose is ed.
Prepare the lter system
Venng the appliance
» When commissioning the appliance for the
rst me, please note that it must be vented
manually.
» To do this, observe the item numbers in gure A and unscrew the bleed screw
3
from the appliance.
» Water must run into the lter housing on its own.
» If water comes out of the vent opening, close it again with the vent screw
3
.
Establish power supply
Operaon with PV panel
» Connect the connecon cable of the device to the PV panel and ghten the union nut by hand.
Operaon with oponal power supply unit
» When operang with mains voltage, only use the oponal mains adapter.
» The appliance may only be connected to a circuit protected by an RCD switch (residual current device) with
a tripping current of 30 mA.
» Connect the connecon cable of the appliance to the power supply unit and ghten the union nut by hand.
Operaon
WARNING!
Danger to life due to operaon of the water treatment system while bathing!
Hair or items of clothing can be sucked into the sucon opening of the pool and, in extreme cases, trap people
under water and prevent them from surfacing.
» Never operate water treatment system devices while people are in the pool.
» Prevent all access to the pool while water treatment system devices are in operaon.
ATTENTION!
Risk of injury!
A damaged device or damaged accessories can lead to injuries.
» Check the appliance and accessories (see chapter Checking).
NOTE!
Flocculants in the bath water can cause the Filter Balls or Filter Wool Flakes to clump together and severely
impair their cleaning eect.
» Do not use occulants for water treatment if you are using Filter Balls or Filter Wool Flakes as a lter
medium.
Commissioning
Ensure that all hoses and pipes are connected correctly and that the water level in the pool is at least 2.5 to 5
cm above the opening of the sucon pipe.
Operaon with PV panel
If the device is operated with the PV panel, the pump starts operang automacally when there is sucient
sunlight.
Operaon with oponal power supply
If the device is operated with the power supply unit from the accessories, operaon starts as soon as the
power supply has been established.
Maintenance instrucons
Algae, bacteria and other microorganisms cannot be ltered by the device.
» Use special water care products to prevent and remove them in order to ensure hygienically perfect water.
» Seek advice from a specialist and observe the dosing quanes.
Maintenance
Change lter medium
The lter medium used (Filter Balls or Filter Wool Flakes) is subject to a certain amount of wear and tear, even
when operated as intended under opmum condions, and should be replaced at regular intervals depending
on the operang me and degree of soiling.
4. Switch o the appliance by unplugging the mains plug or disconnecng the PV panel.
5. Close the shut-o valves or block the water ow to the connecng hoses of the pool.
6. Disconnect the connecng hoses from the pool and the appliance.
7. Completely drain the water from the lter vessel.
8. Dismantle the clamping ring.
de de