9. Slowly turn the lter bowl upside down and empty the lter medium used.
10. Rinse the lter bowl with clear water.
11. Fill in the new lter medium and close the lter bowl again with the clamping ring and lid.
The lter medium has been changed.
Cleaning
Only clean the appliance with a standard bathroom cleaner, clean tap water and a lint-free cloth. Aggressive
cleaning agents can damage the appliance. Dry the appliance with a lint-free cloth.
Examinaon
Check the following before each use:
» Is there any recognisable damage to the device?
» Is there any recognisable damage to the controls?
» Are the accessories in perfect condion?
» Are all pipes in perfect condion?
» Is the inlet not blocked?
» Are the venlaon slots clear and clean?
Do not operate a damaged appliance or accessories. Have it checked and repaired by the manufacturer or its
customer service or a qualied specialist.
Storage
Store the device in a dry and frost-free place (>= +5 °C) without direct sunlight. Always store the dried
lter medium separately from the lter bowl above the lter bowl. Winter.
As soon as the outside temperature permanently falls below +5°C, the pump should be winterised to prevent
damage due to ice formaon (frost blasng).
Winterising
1. Switch o the appliance by unplugging the mains plug or disconnecng the PV panel.
2. Close the shut-o valves or block the water ow to the connecng hoses of the pool.
3. Dismantle the connecng pipes to the pool and drain the hoses.
4. Li the appliance and empty it via the two connecons.
5. Empty the lter medium (see Changing the lter medium).
6. Rinse the appliance with tap water.
7. Allow the appliance to dry completely.
The appliance can be winterised.
de de
Troubleshoong
Problem: Cause: Soluon:
Too lile water ow. The lter medium is dirty. Remove and wash the lter
medium by hand. Replace the
lter medium if necessary.
The water level in the pool is too
low.
Check the water level in the
pool and top up with water if
necessary.
Air bubbles come out of the inlet
nozzle.
The pump sucks in air. Check all hoses and seals for leaks.
Tighten the hose clamps.
Check the water level in the
pool and top up with water if
necessary.
The device does not start. Power supply is restricted or
interrupted.
Too lile sunlight. Check the
locaon, me of day and weather
condions.
When operang with the
oponally available power supply
unit, check the external power
supply.
If the fault cannot be reced, please contact an authorized specialist or the Steinbach support team.
Technical data
Item number: 040601
Boiler size: 290 mm
Connecon diameter: Ø 32 mm
Flow rate: 3.500 l/h
Water content: bis zu 19.000 l
Water temperature: 10°C – 35°C
Funcon principle: not self-priming
Item number: 040602
Cell type: Monokristallin
Number of PV panels: 4
Connector plug: 2-poliger Rundstecker
Maximum Power: 80 W
Maximum power current: 3,33 A
Timer: nein
Pre-lter: nein
Power supply: 24 V
Flow rate: 4.500 l/h
Delivery head: 3,5 m
Filter Balls: 256 g
Maximum power voltage: 24 V
Open circuit voltage: 28,32 V
Short circuit current: 3,67 A
Best working temperature: 15°C – 45°C
Ambient temperature: 0 °C – 60°C
Protecon class: IP65