Error Codes
Display Description Cause/Corrective Action
E FL
Fill Error Fill level is not reached within 30 minutes (or other programmed length of time) in
any fill step.
E dL
Door Lock Fatal
Error
Door is unlocked during a running cycle. To clear this error, cycle power to the ma-
chine.
E dL1
Door Lock Non-
Fatal Error
If the door fails to lock in twenty (20) seconds in Door Locking Mode after the Drive
has been enabled the control will turn off all outputs and show the error E dL1. To
clear this error the door must either open or lock.
E dL2
Door Unlock Non-
Fatal Error
If the door fails to unlock in 20 seconds, with a solenoid type door lock, after the drum
has stopped spinning, and all other outputs have been turned off, the control will show
error E dL2. To clear this error the door must unlock or open.
E door
Door Opened Dur-
ing A Running Cy-
cle
Control detects door open and door locked inputs high. Can be caused by pulling on
door while locked or about to lock. Correct inoperative door locking system. Unpower
machine to clear error.
E Ub1
Non-Fatal Unbal-
ance Error
Unable to balance load. Redistribute load and run cycle.
E Ub2
Fatal Unbalance
Error
Wires to unbalance switch broken or not connected.
CLoSE door
Door Open Indica-
tor
Door is not closed during an active cycle. If door is closed, check for improper wiring
or faulty door switch.
Coin Error
Coin Error Invalid coin pulse or inoperative coin sensor. Check coin drop area and remove ob-
structions. If error persists, tampering may have occured. Evaluate security proce-
dures.
E id
Board ID Incorrect replacement control. Replace user control or output board with the correct
part.
E dS
Brownout/Voltage
Configuration
Unexpected supply voltage. Check the harness connections between the user control
and the output board.
E nr
Drive/Output
Board Not Ready
Hardware failure. Try cycling power to machine before replacing output board.
E bS
Drive/Output
Board Shorted
Hardware failure. Try cycling power to machine before replacing output board.
E Co
Drive/Output
Board Comunica-
tion Error
Communication failure. Power down, power up and try again. If error persists, check
connection between user control and output board, or try replacing the user control or
the output board.
E dr
Drain Error If the control has the drain error enabled the control will enter Machine Error Mode
when the water height is not below the empty level, after attempting to drain for the
programmable time (default 15 minutes). In the event of a drain error, the control will
turn off all outputs and turn on the Machine Error Tone for 15 seconds.
Table continues...
Error Codes
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
110 Part No. 807870ENR4
Bekijk gratis de handleiding van Speed Queen FV6010WN, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Speed Queen |
| Model | FV6010WN |
| Categorie | Wasmachine |
| Taal | Nederlands |
| Grootte | 14039 MB |