Speed Queen FV6010WN handleiding
Handleiding
Je bekijkt pagina 109 van 119

Error Codes
Following is a list of possible error codes for an electronic con-
trol. Errors beginning with EC refer to card reader errors. All oth-
er errors refer to machine errors.
NOTE: Fatal Errors will show oUt oF ordEr along with
the error on the display.
Error Codes
Display Description Cause/Corrective Action
ECXX
Payment System
Error
The Front-end control communicates with the Payment System in order to perform
vending transactions. If an error should occur, which, terminates communication dur-
ing a transaction, the LED Display will show ECXX for a control generated error,
where the XX represents an error code.
EC02
Time-out Error Communication failure. Try card again.
EC03
Invalid Command
Code
Communication successful, but the command was not valid for this machine type, or
the control could not perform the command in its current mode of operation. Ensure
data is for current machine type and control is in correct mode.
EC05
Invalid or Out-of-
Range Data
The value in at least one of the programming options is invalid or out of range. Re-
check the programming option’s value and try again.
EC11
No Card Reader
Initialization
Communication is valid, but there is no card reader initialization. Power down, power
up and try again.
EC18
No Communica-
tion
Card reader is initialized, communication lost. Power down, power up and try again. If
error persists, replace control or card reader.
EC19
No Card Reader
Communication
Communication failure. Power down, power up and try again. If error persists, replace
control or card reader.
Right most deci-
mal point Lit
Network Commu-
nication Error
Communication problem. Wait for 1.5 minutes for error to clear. If error doesn’t clear,
power-down and power-up the machine. If error persists, replace control or network
board.
Right most deci-
mal point Lit
Water Leak Detec-
tion Error or Slow
Drain Detection
Error
Water leak test has detected a water leak during a cycle or slow drain is detected in the
drain step of a running cycle. The decimal point will remain lit after the error display
has expired. Clear the decimal point by pressing the START keypad three times within
five seconds or by cycling the power to the machine.
Left most decimal
point blinking one
second on/one sec-
ond off
Max Speed Fail
Error
If the final spin fails to reach 1200 RPM, the control will set the Max Speed Fail Error
immediately when entering End of Cycle Mode to alert that the max speed was not
reached in the cycle.
This error will be cleared when vend is entered, a key is pressed, the door is opened,
or when higher priority errors are cleared.
ALArn
Break-in Alarm
Error
Check the service door and coin vault switches.
oFF
Break-in Alarm
Shutdown Error
Check the service door and coin vault switches.
Table continues...
Error Codes
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
109 Part No. 807870ENR4
Bekijk gratis de handleiding van Speed Queen FV6010WN, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Speed Queen |
| Model | FV6010WN |
| Categorie | Wasmachine |
| Taal | Nederlands |
| Grootte | 14039 MB |