Handleiding
Je bekijkt pagina 41 van 164

41
is judged to be invalid (Invalid). If “No Assign” is
set to “Priority”, the “IP Input” is invalid (Invalid).
Example: When “Clean Switch” is set as
“Disable”
(bandwidth for available input: 24G)
IP Input1 Priority1 2160/50P 12G Valid
IP Input2 Priority3 1080/50P 3G Invalid
IP Input3 Priority2 2160/50P 12G Valid
IP Input4 Priority4 1080/50P 3G Invalid
Example: When “Clean Switch” is set as
“E
na
ble” (bandwidth for available input: 12G)
IP Input1 No Assign 2160/50P 12G Invalid
IP Input2 Priority4 1080/50P 3G Valid
IP Input3 Priority3 2160/25P 6G Valid
IP Input4 Priority2 1080/50P 3G Valid
After setting, when you try to move to the
upper layer menu without executing Cancel or
Confirm, a message for executing Cancel or
Confirm is displayed. Select either one and
execute it.
"JPEG XS" under "V Compression" can be set
when the optional "BVML-JD10" license (sold
separately) is activated.
User Color Temp.
You can select and adjust the color temperature.
When using a measurement instrument for color
temp
erature adjustment, Konica Minolta Color
Analyzer CA-310/410 is recommended.
Submenu Setting
User Color Temp. Select the color temperature setting to
be adjuste
d.
Name Sets the color temperature name.
R/G/B Gain Adjusts the color balance (gain) of R
(r
ed)/
G (green)/B (blue).
R/G/B Bias Adjusts the color balance (bias) of R
(red)/G (green)/B (blue). (Default
value: 0)
Notes
Check the black level with the
PLUGE signal, etc. after adjusting
the color temperature, and adjust
the black level under “Brightness”
of “Chr./Bright./Cont.” in “Ch.
Setting” as necessary.
When “Out. Image(Single)”
(page 87) of the “Enhanced Out.”
menu is set to “Fixed”, the color
t
emper
ature cannot be adjusted.
When adjusting the color
temperature, change “Out.
Image(Single)” to “Displayed”.
Copy From Select from the following items to copy
th
e s
elected color temperature data.
D65
D93
D60
D50
DCI
DCI XYZ
User1 to User10
Note
The color temperature data is used
commonly regardless of the signal
format or the EOTF setting. When the
color temperature is adjusted under
certain conditions, the adjusted result
is reflected in all displays on which the
same color temperature data is set.
Signal Select the signal to adjust the color
temperature. (Default value: Internal)
Internal: Select to adjust the color
temperature by using the
internal signal. For XYZ format
s
ignal
s, this unit displays the
internal signal equivalent to
D65 48 cd/m
2
.
External: Select to adjust the color
temperature by using the
signals input from an external
device.
Note
For the XYZ format signals, set the
contrast to 192 to change the standard
brightness (at SDR 100 % white signal
input) to 48 cd/m
2
.
Submenu Setting