Sommer ENTRAcode+ handleiding
Handleiding
Je bekijkt pagina 30 van 36

30
10. Operation / Operation in Extended mode
Activating transmission delay / dening the
time
A
#
3 4
7
8
B
C
A. Enter the key combination above in the order shown.
B. Enter the desired transmission delay time in seconds
(in the example here, 8 seconds).
A. Press the
*
key.
⇒ The green and red LED light up for 2 seconds
⇒ During this time, the backlighting goes out
✔ Transmission delay has been activated
✔ Desired time for the transmission delay has been set
Deactivating the transmission delay
#
3 4
A. Enter the key combination above in the order shown.
⇒ The green and red LED light up for 2 seconds
⇒ During this time, the backlighting goes out
✔ Transmission delay has been deactivated
10.6 Active time
NOTE
When this function is activated, the radio
command can be sent again within 20
seconds after entry of a valid PIN code by
pressing any key on the keypad.
Application example: Stopping a garage
door quickly
► The red LED ashes cyclically while the
active time is running down.
► Can be used in both operating modes.
► In order to activate the active time on the
battery-operated version ENTRAcode+ AP,
rst press the # key for 5 s to wake the de-
vice from power-saving mode.
► On the battery-operated version
ENTRAcode+ AP, rst press the # key to
wake the device from power-saving mode.
A
#
1 2
► Enter the key combination above in the order shown.
⇒ The green and red LED light up for 2 seconds
⇒ During this time, the backlighting goes out
✔ Active time has been activated
10.7 Transmission delay
NOTE
After activation of this function and following
entry of the correct PIN code, the radio com-
mand is only transmitted after the expiry of a
selectable period of time.
Application example: It is necessary to cov-
er a certain distance to the door or the gate
after entering the PIN code.
► Setting range:
In Standard mode: 1, 3, 5, 7, 9 s
In Extended mode: 0 - 9 seconds.
► Here, it is necessary to pay attention to the
double assignment of the keys "10.2 En-
tering a sequence of digits in Extended
mode" on page 28.
► The red LED ashes cyclically while the
transmission delay time is running down.
► On the battery-operated version
ENTRAcode+ AP, rst press the # key to
wake the device from power-saving mode.