Sommer ENTRAcode+ handleiding
Handleiding
Je bekijkt pagina 29 van 36

29
10. Operation / Operation in Extended mode
10.5 Changing the PIN code
p. "9.2 Entering a sequence of digits in Standard
mode" on page 24
Example code 4712
A
1
2
B
1
2
1
2
1
2
C
3
4
D
7
8
1
2
1
2
E
A. Press the
*
key.
B. Enter current PIN code.
⇒ Backlighting flickers for 1 s
C. Press the
*
key.
D. Enter new PIN code (in the example shown here,
4712).
E. Press the
*
key.
⇒ The green and red LED light up for 2 s
✔ PIN code has been changed
10.3 Unlocking the ENTRAcode+
NOTE
In as-delivered state, the ENTRAcode+ is
locked and no input is possible. The device
must be unlocked before initial commission-
ing.
#
► Press and hold the # key for 5 s.
⇒ Red, green LED and backlighting
blink
⇒ Red and green LED go out
⇒ Backlighting lights up
✔ ENTRAcode+ was successfully unlocked
10.4 Standard PIN codes
NOTE
► Each ENTRAcode+ is programmed with the
same standard PIN codes at the factory.
► For security reasons, the standard PIN
codes must be changed before programming
on a radio receiver!
► On the battery-operated version
ENTRAcode+ AP, rst press the # key to
wake the device from power-saving mode.
Radio commands 5
Maximum code length 8 digits
PIN codes
Command 1 1111
Command 2 3333
Command 3 5555
Command 4 7777
Command 5 9999