Sommer ASB-6010A handleiding

61 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 45 van 61
45
Troubleshooting
Fault Possible cause Corrective action
Connected warning light does not light up. Light bulb defective. Replace light bulb.
Check the supply line.
No operating voltage at light bulb.
Connected warning light does not light up / blink
during opening / closing. LED WARNING lights
up / blinks.
Lighting activated during movement / pre-warning
time activated.
Set warning light to blinking with SOMlink.
Warning light blinks with the following pattern:
Induction loop detector activated before or during
movement.
Remove all metal objects in the area of the
induction loop.
Repair induction loop or induction loop
detector.
Speed changes during opening and closing. No fault. Completely normal: before the end positions
are reached, the barrier reduces speed
(soft run).
Warning light blinks with the following pattern:
Operator or control unit defective. Have it checked and, if necessary, operator
or components replaced by a specialist.
Warning light blinks with the following pattern:
Service required (e. g. pre-set limit value
reached).
Have service performed by a qualied
specialist.
The barrier can only be operated as long as
the button of a command device is pressed.
Dead man operation activated. Deactivate dead man mode with SOMlink.
Barrier is open and cannot be closed. Warning
light blinks. Warning light blinks with the following
pattern:
LED warning light blinks with the following
pattern:
Alarm safety input open, e.g. re alarm system
activated or jumper defective.
Close Alarm safety input, reset re alarm
system and carry out power reset.
Repair jumper and carry out power reset.
LED START 1 / START 2 constantly lit. Constant signal at button connection 1 or 2. Check connected command devices.
An external signal is interfering with the control
unit of the barrier; LED CH1, CH2, CH3 or CH4
lights up on the control unit.
Wait until the external signal falls o󰀨.
Remove the sources of the interference
emitting the external signal.
Boom is hanging down. The boom was bent with force or pressed up
or down when in the closed position.
Have barrier adjusted or repaired by
a specialist.
LED CH1, CH2, CH3 or CH4 lights up
continuously.
Radio signal is being received; the button of
a handheld transmitter may be defective or
an external signal is present.
Remove the battery from the handheld
transmitter.
Wait until the external signal falls o󰀨.
LED CH1, CH2, CH3 or CH4 lights up for
30 seconds.
The radio receiver is in programming mode
and waiting for a radio code from a handheld
transmitter.
Press the desired handheld transmitter
button.
Barriers with oating support only
The oating support of the barrier hits the
ground hard in the lower end position.
The lower end position of the barrier has been
incorrectly set, which means that the distance
between the oating support and the ground is
too small. In closed state, the distance between
the oating support and the ground must be
about 2 cm.
If necessary, correct the lower end positions
of the barrier; see "Setting the end position
(optional)" on page 25.
If you cannot nd the malfunction in the table and eliminate it, carry out the following measures.
Perform a control unit reset and then reprogramme the force values
Set all DIP switches to OFF
Disconnect the connected accessories (e.g. photocell) and reconnect the jumper for a safety connection
Check all connections
If you encounter other problems, please contact your specialist dealer,
a customer service company: https://www.sommer.eu/de/servicepartner.html,
our free service hotline:
+49 (0)900-1800150
(0.14 euros/minute from a German landline, mobile prices may vary)
or visit our website at: https://www.sommer.eu/de/