24
Attach assembly to hull
1 Flip the transducer and fairing block over, so the transducer stem is upward.
2 Apply a uniform layer of sealant to the upper face of the lower part of the fairing block. This is the
surface that will be in contact with the bottom of the hull. The layer of sealant should be approximately 
2 mm (
⁄ in) thick.
3 From outside the hull, feed the transducer cable through the large hole in the hull.
4 Fit the transducer stem and anti-rotation stud through the holes in the hull. Apply gentle pressure to
the assembly to secure the lower half of the fairing block and attached transducer to the hull in its nal 
position.
¼ Note: The transducer must be supported in position outside the hull (E, below) until you have installed and
tightened the nuts on the transducer stem and anti-rotation stud.
B
D
C
A
EE E
Cross-secon view
A Transducer stem at forward/bow end
B Hull with drilled holes
C Bottom part of fairing block
D Transducer
E Support the transducer until installation is complete