9.10 Recording an audio manually
The Audio function allows the sound signal from the sound level meter transduction chain to be rec-
orded at the same time as the measurement parameters. The signal thus recorded can be used for re-
play by means of an audio playback program or through the NS-ENS software module. The instru-
ment allows recording to be triggered either manually or automatically through user-settable trigger
functions. Manual and automatic modes can also be used in conjunction during a measurement.
Info
To setup the instrument correctly, please refer to the chapter “10.3 Setting audio re-
cording parameters” on page 69.
Notice!
With this function, audio recording and measurement recording are carried out simul-
taneously.
1
Start a measurement with recording, see chapter “9.9 Starting
and stopping a measurement with datalogging ” on page 63.
2
The measurement with recording is running (see the red circle
recording icon in the upper right corner).
3
Tap the "audio" icon on the left to start an audio recording.
4
The audio recording icon turns green when audio recording is
active. The icon in the upper right corner indicates the status of
audio recording.
5
Tap the "audio" icon again to stop audio recording.
6
Tap the right icon to stop recording the measurement.