MC1448 and MC1848
Air and Water Cooled User Manual
June 2022
Page 9
Plumbing Requirements
All models require connection to cold, potable water.
A hand actuated valve within site of the machine is
required.
Air cooled models have a single 3/8” FPT inlet water
connection.
Water cooled models have a 1/2" FPT drain tting
plus an additional 3/8” FPT condenser inlet water
connection.
Water Filters
If connecting to water ltration, lter only the water
to the reservoir, not to the condenser. Install new
cartridges if the lters were used with a prior machine.
A triple head lter is recommended. Either the
Scotsman SSM3 taste and odor lter system, or the
ADS-AP3 AquaPatrol™ system.
Drains
All models require drain tubing to be attached to
them. Air cooled models have a single 3/4” FPT drain
tting in the back of the cabinet. Water cooled models
have the same tting plus an additional 1/2” FPT drain
tting in the back of the cabinet. Install new tubing
when replacing a prior ice machine, as the tubing will
have been sized for the old model and might not be
correct for this one.
1. Connect water supply to water inlet ttings.
Note: This NSF listed model has a 1" anti-back
ow air gap between the end of the water inlet tube
and the highest possible reservoir water level, no
additional back ow device is required for the potable
water inlet.
2. Connect drain tubing to drain ttings.
3. Route the drain tubing to building drain. Follow
local codes for air gap.
Use rigid drain tubes and then route them separately
– do not Tee into the bin’s drain or, if water cooled,
Tee the condenser drain into the reservoir or bin drain.
Vent the reservoir drain. A vertical vent at the back of
the drain, extended about 8 - 10” will allow the gravity
drain to empty and also keep any surges during
draining from discharging water out the vent.
Insulate drain tubing if in a humid environment.
Horizontal runs of drain tubing need a 1/4” per fall per
foot of run for proper draining.
Follow all applicable codes.
Water Fitting
Field Supplied
Inlet Water Connection
Water Inlet
Connection
Potable Water
Supply
Optional Water
Filters
Plumbing Connections
Water Cooled
Condenser Drain
Water Cooled
Condenser Inlet
Floor Drain
Reservoir
Drain