Handleiding
Je bekijkt pagina 47 van 52

English-47
INSTALLATION
05
3. Press the Air swing button and check the following:
The airflow blades work properly.
4. Press the Power
button to stop the operation.
• When you complete the installation successfully, hand over this manual to the user for storage in a
handy and safe place.
NOTE
Pump down procedure (when removing the product)
1. Turn on the air conditioner and select Fast or Cool mode. Please let the compressor run for more than 5
minutes. If the compressor does not operate for more than 5 minutes due to protection control, wait about 2
minutes, and then carry out the next procedure.
2. Release the valve caps on High and Low pressure side.
3. Use L wrench to close the valve on the high pressure side.
4. Approximately 1 minutes after, close the valve on the low pressure side.
5. Stop operation of the air conditioner by pressing the Power button on the indoor unit or remote controller.
6. Disconnect the pipes.
RAC TCL ODM 아프리카향 IBIM_EN_Ver.1.0.indd 47 2019-04-08 오후 1:24:13