ENGLISH-6
Safety precautions
▶ This product contains uorinated gases that contribute to global greenhouse effect. Accordingly, do not
vent gases into the atmosphere.
▶ For installation with handling the refrigerant(R-32), use dedicated tools and piping materials. Working
pressure of R-32 is higher than R410A, So failure to use the dedicated tools and piping materials may
cause rupture or injury. Furthermore, it may cause serious accidents such as water leakage, electric shock
or re.
▶ Servicing shall be performed as recommended by the manufacturer. In case other skilled persons are
joined for servicing, it shall be carried out under supervision of the person who is competent in handling
ammable refrigerants.
▶ For servicing the units containing ammable refrigerants, safety checks are required to minimise the risk
of ignition. R-32 is slightly more ammable than R410A hence additional precautions are required when
dealing with it.
▶ Servicing shall be performed following the controlled procedure to minimize the risk of ammable
refrigerant or gases.
▶ Do not install where there is a risk of combustible gas leakage.
▶ Do not place heat sources.
▶ Be cautious not to generate a spark as follows:
- Do not remove the fuses with power on.
- Do not disconnect the power plug from the wall outlet with power on.
- It is recommended to locate the outlet in a high position. Place the cords so that they are not tangled.
▶ If the indoor unit is not R-32 compatible, an error signal appears and the unit will not operate.
▶ After installation, check for leakage. Toxic gas may be generated and if it comes into contact with an
ignition source such as fan heater, stove, and cooker, cylinders, make sure that only the refrigerant
recovery cylinders are used.
▶ Never directly touch any accidental leaking refrigerant. It could result in severe wounds caused by
frostbite.
Power supply line, fuse or circuit breaker
▶ Always make sure that the power supply is compliant with current safety standards. Always install the air
conditioner in compliance with current local safety standards.
▶ Always verify that a suitable grounding connection is available.
▶ Verify that the voltage and frequency of the power supply comply with the specications and that the
installed power is sufcient to ensure the operation of any other domestic appliance connected to the
same electric lines.
▶ Always verify that the cut-off and protection switches are suitably dimensioned.
▶ Verify that the air conditioner is connected to the power supply in accordance with the instructions
provided in the wiring diagram included in the manual.
▶ Always verify that electric connections (cable entry, section of leads, protections…) are compliant with
the electric specications and with the instructions provided in the wiring scheme. Always verify that all
connections comply with the standards applicable to the installation of air conditioners.
▶ Devices disconnected from the power supply should be completely disconnected in the condition of
overvoltage category.
▶ Be sure not to perform power cable modication, extension wiring, and multiple wire connection.
- It may cause electric shock or re due to poor connection, poor insulation, or current limit override.
- When extension wiring is required due to power line damage, refer to Step 5 Optional: Extending the
power cable in the installation manual.