waveforms will move up and down on the screen. Press down the knob to reset
the vertical position to zero.
- Vertical SCALE: channel vertical scale knob. Rotate this knob to modify the
amplitude of each vertical grid of the selected waveform, making its amplitude
increase or decrease. Press down this knob to switch between the coarse and
fine adjustment of the vertical scale.
-
: reference waveform key. Press this key to enter the reference waveform
setting interface. You can compare the actually measured waveform with the
reference waveform to locate the circuit failure.
-
: math operation key. Press this key to enter the math operation
interface. The math operations include A+B, A-B, A×B, A/B, and FFT. Besides,
you can also set the math operation label.
-
: indicates the logic analyzer key. Press this key to open the logic
analyzer control menu. You can enable or disable any channel or channel group,
modify the waveform size of the digital channel, modify the threshold of the
digital channel, and group the 16 digital channels. Besides, you can also set a
label for each digital channel.
-
, : indicates the Function/Arbitrary Waveform Generator setting
key. Press GI to enable or disable the output of the [GI] connector on the front
panel; press GII to enable or disable the output of the [GII] connector on the
front panel; and then enter the corresponding signal source setting interface.
Enable or disable the status display of the current signal.
-
, , , : analog channel key. Press the specified key to
enable or disable the specified channel.
- If the channel is not displayed, you can press the channel key to open the
channel in the waveform view window.
- If the channel is displayed but not selected, you can press the channel key to
select the channel.
- If the channel is both displayed and selected, you can press the channel key
to close its display in the waveform view.
11. Probe Compensation Signal Output Terminal/Ground Terminal
This terminal outputs the probe compensation signal which helps you match a
probe's input capacitance to the oscilloscope channel to which it is connected.
12. Horizontal Control Area
Quick Start
MHO2000 User Guide
26
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Bekijk gratis de handleiding van Rigol MHO2034, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkRigol
ModelMHO2034
CategorieNiet gecategoriseerd
TaalNederlands
Grootte47982 MB