Rigol MHO2034 handleiding
Handleiding
Je bekijkt pagina 195 van 332

• When set to ON, the waveform of the digital channel is displayed in high priority.
The waveforms of the analog channels are overlaid.
12.2.4 To Set the Probe Delay
To avoid measurement result errors arising from the transmission delay of the probe
cable, you can set the probe delay on the oscilloscope.
In the LA interface, click or tap the Other Settings tab to enter the other settings
interface. Click or tap the input field of Probe Delay to set the probe delay with the
pop-up numeric keypad. Its range is from -200 ns to 200 ns. By default, it is set to 0 s.
You can also use the Up/Down arrow to adjust the probe delay. Also, if no probe
delay is required, you can directly click or tap 0 to reset it to zero.
Digital Channel
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. MHO2000 User Guide
177