16
in the scan list are break-before-make
[1]
. You can close multiple channels on this
module only if you have not configured any channel to be part of the scan list.
The 4 current channels are used in combination with the DMM module to
perform DC current or AC current measurement. All channels in the scan list are
break-before-make
[1]
. In any case, you cannot close multiple channels on this
module.
This module can be connected with MC3065 (DMM Module, if MC3065 is
currently inserted).
For the specifications of this module, please refer to the User Guide or Data
Sheet of this product.
Note
[1]
:
break-before-make
means that only one channel can be closed at each time. For
voltage channels (channel 1 to channel 20), it is always to open the connection between the
channel and the DMM module before closing the connection between the next channel and
the DMM module during a scan. For current channels (channel 21 to channel 24), the
following operations are performed during a scan: to close the short relay of the channel, to
open the connection between the channel and the DMM module, to close the connection
between the next channel and the DMM module and to open the short relay of the next
channel.
6 MC3416 (16-Channel Actuator):
MC3416 can connect signal to the device under test or enable external device.
Any of the 16 channels can switch to Normally-Open (NO) and Normally-Closed
(NC) states.
For the specifications of this module, please refer to the User Guide or Data
Sheet of this product.
7 MC3534 (Multifunction Module):
It provides 3 kinds of functions with 4 channels for each function. This module
can be used to check status or control external device (such as the solenoid,
power relay and microwave switch). You can also read the digital inputs and the
totalizer count during a scan.
Four 8–bit digital input/output (DIO) ports
4 totalizer (TOT) input terminals (the first two channels are 10 MHz TOT and
the other two channels are 100 kHz TOT) with 1 Vpp sensitivity
4 analog output terminals, ±12 V calibrated voltage
For the specifications of this module, please refer to the User Guide or Data
Sheet of this product.
8 MC3648 (4×8 Matrix Switch):
MC3648 is used to connect multiple devices to multiple points on the device
under test. You can connect the rows and columns of multiple matrix switches to
form relatively larger matrix (such as 8×8 and 4×16, the number of cross-points
cannot exceed 160).
32 two-wire cross-points which can connect any combination of inputs and
outputs at the same time. For the specifications of this module, please refer to
Bekijk gratis de handleiding van Rigol M302, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.