SAFETY, WARNINGS, INSTALLATION NOTES
9
Mains pressure water supply
The water heater is designed to operate at mains pressure by connecting directly to the mains water supply.
The maximum mains water supply pressure for the water heater is 1,000 kPa. If the mains supply pressure in
your area exceeds 1,000 kPa, an approved pressure limiting valve that does not have non-return valve
characteristics (such as an RMC PSL series valve) must be installed.
A minimum water supply pressure of 120 kPa is required to achieve the rated flow and performance of the
water heater.
Refer to “Mains Water Supply” on page 23 for additional information.
Mounting of the water heater
This water heater must be installed vertically upright with the water, gas and power connections on the
underside, pointing toward the ground. The back of the water heater can be either against a wall or supported
by a frame. The water heater must be well secured to the wall or frame using two fasteners, suitable for the
wall or frame type, each at the top and bottom of the unit. Refer to the note on page 21 for additional
information.
Alternatively, the water heater can be installed recessed into a wall, using a proprietary made recess box from
Rheem for such an installation. Refer to the installation instructions which accompany the recess box kit for
the dimensions of the space required and information on its installation.
Refer also to “Recess Installation” on page 23.