INSTALLATION
23
PIPE COVER
The pipe work to the water heater can be housed within a pipe cover. A pipe cover kit (Rheem Part 299426)
is available for such an installation. Refer to the installation instructions which accompany the pipe cover kit.
RECESS INSTALLATION
The water heater can be installed recessed into a wall. A recess box (Rheem Part 299427) is available for
such an installation. Refer to the installation instructions which accompany the recess box kit for information
on its installation.
The rating plate on the side of the water heater should be moved to or the information on it, including the water
heater serial number, manufacture date and model number, indelibly copied onto either the front panel of the
water heater or to another position which is visible when the water heater is installed so the householder or
responsible officer can access the water heater details when required. An additional rating label is supplied
attached to the inside of the front cover of the water heater. This is for a service person to access the water
heater details when required.
Note: If the recess box is under a covered area, refer to “Installation within a Covered Area” on page 22.
MAINS WATER SUPPLY
Where the mains water supply pressure exceeds that shown in the table below, an approved pressure limiting
valve that does not have non-return valve characteristics (such as an RMC PSL series valve) is required and
should be fitted as shown in the water and gas connection detail diagram on page 33.
Model
12 to 26
Relief valve setting
1750 kPa
Maximum mains supply pressure
1000 kPa
Minimum mains supply pressure *
120 kPa
* minimum water supply pressure required to achieve the rated flow
and performance
Notes
It is not recommended to install this water heater with a low pressure water supply.
A minimum water supply pressure of 120 kPa is required to achieve the rated flow and performance of
the water heater.
If this water heater is installed as an in-series gas booster for a solar water heater, the maximum water
supply pressure to the solar water heater, without an expansion control valve (ECV), is generally 800 kPa,
however it may be less than this for some models. Refer to the Owner’s Guide and Installation Instructions
supplied with the solar water heater for maximum mains supply pressure details.
If sludge or foreign matter is present in the water supply, it is recommended a suitable filter be incorporated
in the cold water line to the water heater.
This water heater is not suitable for connection to bore water or spring water unless a water treatment
device is fitted.
Refer to “Water Supplieson page 16 for further information on water chemistry.