DETAILED INSTRUCTIONS
Press the reset/learn button (see fig. CENTRAL UNIT,
point 7)
and hold it down for 10 s in order to delete
all the learned transmitters. The reset routine is shown
with a single beep as an acoustic signal and functions
correctly if all the LEDs are flashing green.
If only the power LED is flashing green then the table
definitely needs to be deleted, which is initiated by
keeping the reset button depressed again. The central
unit will respond with 2 acoustic signals, a pause and
another 2 acoustic signals and the power LED will be
reset to being lit constantly.
Release the reset button again after these signals. The
sensor table and the corresponding flash memory in
the device have now been deleted. This is shown by
the constant lighting of the power LED. None of the
corresponding sensor LEDs should be lit.
Encoding
The following steps are necessary to teach the
relevant sensors:
Pairing can now be initiated by briefly pressing the
reset/learn button. This is shown by a short acoustic
signal and all the LEDs flashing green.
The transmitters are now paired individually.
The set button on each sensor is activated and this is
answered by the sensor by flashing red-green.
(The same LED signal is also displayed when the
SET routing is running)
After approx. 10 seconds the LEDs on the central
unit display which sensor type was taught and one or
several acoustic signals will sound again in accordance
with the number of sensors that have already
been taught.
CAUTION!
An AND-linking of the sensors is created by setting
the jumper in AND position for all transmitters ex-
cept the last one. The jumper of the last transmitter
must be set to the OR position.
Completion of the teach-in process has failed if
the last transmitter to be taught-in is set with the
jumper in the AND position and then a furnace
transmitter is to be taught-in. The control unit then
reports an error (3 short beeps, 3 long beeps,
3 short beeps) and the teach-in process must be
repeated completely.
When this is done, you can configure another sensor
or just wait, the learning process is automatically
terminated 50 seconds after the last configured
transmitter. This is shown by 2 consecutive acoustic
triple signals and a change of the power LED to
constant green and the corresponding sensor LED to
the relevant status.