21
BLOWN Fuse blown or removed
PSU Temp:
HEATING High Temperature
OK Normal Temperature
If one of the following indications appears, consult the list of faults:
PSU COMMUNICATION LOSS Communication fault with PSU
FLASH FAILURE PSU Microprocessor fault
WATCHDOG RESET PSU Microprocessor fault
The Auxiliary power supply menù allows you to view the status of backup power supply connected to the
buffer batteries:
Aux power status:
DISABLED Disabled (Disablement)
FAULT Faulty
OK Running
Battery Status:
ABSENT Battery pack removed
SHORT Battery pack in short-circuit
REVERSE Battery pack reverse-connected
OVERCURRENT Current protection active, battery pack disconnected
CHARGE LOW Battery pack charge low
IN USE Battery pack in use
Z TEST Battery pack impedance test running
ON CHARGE Battery pack on charge
IDLE Battery pack at rest
Batt temp:
PROBE SHORT Battery pack temperature probe in short circuit
PROBE OPEN Battery pack temperature probe open or removed
OVERTEMP Overheating of the battery pack; temperature out of range
UNDERTEMP Battery pack temperature below threshold.
OK Battery pack temperature correctly in range.
Batt Z: (Battery pack impedance)
ERROR Battery pack impedance out of range, batteries to be replaced
WARNING Battery pack impedance near the error threshold
OK Battery pack impedance correctly in range.
NOTE: If the temperature of the battery pack is in error or the probe is not working, charging and
impedance testing are suspended.
For completeness, the measured voltage value of the battery pack in volts is indicated.
If one of the following indications appears, consult the list of faults:
PSU COMMUNICATION LOSS Communication fault with PSU
FLASH FAILURE PSU Microprocessor fault
WATCHDOG RESET PSU Microprocessor fault
The Battery charger menù allows you to view the status of the battery pack charger.
Charger status:
DISABLED Disabled (Disablement)
FAULT Faulty
OK Properly functioning
Activity:
GENERAL FAULT Charger circuit faulty
ON CHARGE Charging of battery pack
Z TEST Battery pack impedance test running
CHARGER TEST Charger circuit test running