Proel AE604 handleiding
Handleiding
Je bekijkt pagina 20 van 48

20
USRMAN_AE604EN_REV003
Detail:
GROUND SHORT Speaker Line shorted to GROUND
NO LOAD DETECTED Speaker Line interrupted
UNDERLOAD Loss of Line Load
OVERLOAD Increase of Line Load
BAD LOAD Line impedance not manageable
LINE SHORTED Line in short-circuit
From the detail screen of the amplifiers or speaker lines, pressing OK it is possible to access to the POP-UP
in which the commands to insert or remove the "disablement" condition of the section are available.
From the POP-UP, with the section in "disablement" it is possible to perform the calibration of the line
impedance by selecting the "Calibrate line" or "Line autoset" command.
The "Calibrate line" command measures the line impedance of active configured speakers.
The "Line autoset" command measures the impedance of all lines and activates those in which it detects a
load, the others will be disabled.
The execution takes about 40 seconds and the result is reported in the detailed status screens of the
speaker and amplifier lines.
At the end of the calibration it is necessary to remove the disablement.
NOTE: When the "Line & Amp" section is in "disablement" all the safety functions related to the
amplifiers and speaker lines are deactivated. Any "FAULTS" errors are also removed. The "disablement"
function allows you to operate on the speaker lines without interrupting system operation and without
generating "FAULTS" errors.
Men
ù
"Power suppliy & battery"
The Power supply unit menù allows you to view and manage the status of the system power supply unit.
All information is shown in 4 screens selectable with the UP and DOWN arrows:
• Main power Main power supply connected to the primary power mains
• Aux power Backup power supply connected to the buffer batteries
• Charger Buffer battery charger
• Thermal sys Thermal management
Each screen is associated with one of the following status:
DISABLED Disabled (Disablement)
FAULT Faulty
OK Running
You can scroll through them using the UP and DOWN arrows, pressing OK You can access the detail page.
The Main power supply menù allows you to view the status of the Main power supply connected to the
primary power mains:
Main PSU status: (Main Power Supply status)
DISABLED Disabled (Disablement)
FAULT Faulty
OK Running
Mains: (Primary power mains status)
PRESENT Primary power mains connected and present
ABSENT Primary power mains disconnected and absent
Fuse: (System protection fuse status)
OK Fuse intact