Function description of the module
109925_en_04 Phoenix Contact 9 / 60
2.3.1.2 Counting direction
Depending on the parameterization, you specify the counting direction via the CNTn_Dir
output data bits or the CNTn_IN2 (Dirn) direction input.
Via object 0306
hex
, counting direction, you can parameterize the counting direction:
Permanently up or down
Control via counting direction input Dir1/Dir2
Control via the Set_CNTn_Dir bits in the output process data
See Section “Counting direction (0306hex: CNT_Direction)” on page 42.
2.3.2 Controlling outputs
Two outputs are available for each counter channel, which the module triggers based on
the parameterized conditions.
Set the following parameters for this:
For each output, the comparative value you want to use as a trigger
Section “Comparative value (0303hex: CNT_CompareValue)” on page 40
The behavior of the respective output
Section “Output behavior (0307hex: CNT_OutputMode)” on page 44
If you have selected a pulse for the output behavior: the duration of the pulse
Section “Duration of the output pulse (0308hex: CNT_PulseTime)” on page 46
2.3.3 Parameterizing input filters
To minimize interference, you can parameterize input filters for each counter channel:
Source input
Input 1 (IN1, gate input)
Input 2 (IN2, direction input)
Input 3 (IN3)
See Section “Input filter ... (0317hex ... 031Ahex: CNT_InputFilter...)” on page 54.