2.7 Using the provided buffer stripper tool, carefully remove the
buffer exposing the bare fiber.
BUFFER STRIPPING GUIDELINES:
Panduit recommends that you remove no more than 1/4" (6.4mm) of buffer at a time to avoid breaking the fiber.
Refer to cable manufacturer's buffer stripping guidelines for specific recommendations.
Hold the buffer stripper such that the arrow on the tool points in the direction of buffer removal.
Noting the location of the tool's blades, position the fiber in the tool's V-notches. Squeeze the handles firmly, and
pull tool in the direction of the arrow on the tool.
Clean the buffer stripper blades after each strip by holding the handles open, pulling the casings back away from
the blades, and letting them snap back against the blades.
3. ATTACHING FERRULE TO 1.6mm - 2.0mm JACKETED CABLE
Instructions intended for anaerobic adhesive only.
3.1 Clean the bare fiber using an alcohol (90% minimum concen-
tration) soaked lint-free wipe. The fibers should be free of all
coating and residue. Insert fiber without adhesive or primer into
ferrule assembly to ensure a proper fit and to remove any
debris which may be blocking the ferrule hole. Remove fiber,
clean fiber again, and proceed to the next step.
3.2 Apply primer onto the bare fiber with the brush from the primer
bottle, and onto the first 1/8" (3.2 mm) of the buffer next to the
exposed fiber. Set fiber aside such that it will not collect debris
while completing the next three steps.
3.3 Insert the needle of the adhesive filled syringe into the rear of
the connector assembly until it bottoms against the ferrule.
3.4 While pressing the needle firmly against the rear of the ferrule,
gently apply pressure on the plunger until a small bead of
adhesive forms on the front tip of the ferrule. Wait 3 seconds
before removing the needle from the ferrule assembly.
3.5 In a smooth motion, carefully insert fiber into the connector
assembly and through the ferrule. The fiber is fully inserted
when the buffer bottoms against the ferrule. There will be a
slight gap between the cable jacket and the backbone. Do NOT
force the jacket up against the backbone. The adhesive will
begin to set within seconds.
Note: If adhesive oozes out the back of the assembly, you
have injected too much. It is critical to the function of the
connector that you wipe away all excess adhesive.
3.6 Allow one minute for the adhesive to harden before cleaving.
3.7 Clean the needle using a dry lint-free wipe. The needle should
be free of any excess adhesive before preparing the next
connector.
Page 8 of 11
3.5
Gap
Adhesive Bead
3.4
3.1
1/4" (6.4mm) MAX
2.7
2.7
1.6mm - 2.0mm JACKETED CABLE STRIPPING DIMENSIONS
(cont.)