SYNCHRONISATIONOFANUMBEROFUNITS
Itispossibletosynchronizedupto10unitscontemporaneously,throughwire(2poletwistedpairtype,max30mlength)sotohave
modeandinversiontimesynchronized.Whentheunitisswitchedonforthefirsttime,therotationdirectionofeachunit(clockwiseor
anti-clockwise)isautomaticallyestablished.Otherfunctionalitieslikespeed,smarthumiditycontrolandboost,continuetobecontrolled
independently on each single unit.
Wiringdiagramasperfig.17B.
VENTILATIONSYSTEMDISABLE (not available on the SITALI SF 150 model cod.99431)
Whenunitsareconnectedforsynchronizationasdescrivedabove,it’spossibletoswitchoffallunitsusingtheDISABLEinput(fig.18B).
It’ssufficientto connecta switch(or relayoutput) totheDISABLEinputofJUSTONEunit (fig.19B): whenthe contactis closed
(shortened), all units switch off. The units remain switched off until the contact is reopened, whereupon they resume normal operation.
Maintenancecanbecarriedoutbytheuserasshowninfigures52-68.
MAINTENANCE
SPEED LED COLOUR ACOUSTIC SIGNAL
speed 1 single green led short, single
speed 3 double green led short, double
OFF* red led long
*pressthebuttonfor3seconds.
ANOMALY POSSIBLE CAUSE SOLUTION
NoiconshownonthecontrollerLCD
display
Batteriesaredead Change the batteries
Batteriesarenotpresent Check that batteries are in there
Batteriesarewronglypositioned Position the batteries correctly
The icon ashes on the LCD
display
Low batteries Change the batteries
Theunitdoesnotexecutethe
command sent from the remote control
Lack of communication between the unit and the
remote controller
Go closer to the unit, pointing the controller to the
receiver on the left side of the unit
The unit does not operate
There is no voltage Check that the unit is correctly wired to the main supply
Ventilation unit does not couple correctly with the
support base
Check that the coupling is properly done
TheDISABLEinputisclosed OpentheDISABLEinput
Theunitoperatesatthemaximum
speed
TheBoostfunctionalityisactivated,onthedisplay
the icon is shown
Wait until the boost timing ends (15 minutes)
or deactivate the boost function pressing the
button.
Unit speed suddenly increases The smart humidity control is activated
Wait until the smart humidity control phase ends (10
minutes) or deactivate the humidity control function
pressing the button for 5 seconds.
Fixedyellowled Dirtyfiters
Filtersmaintenance/replacementisneeded:reset
filteroperationhastobedone
Fixedredled Antifrost protection is activated Wait until the antifrost phase ends (30 minutes)
Fixedblueled Boostisactivated
Wait until the boost timing ends (15 minutes)
or deactivate the boost function pressing the
button.
Flashing blue led Smart humidity control is activated
Wait unitl the humidity control phase ends (10
minutes)
Fixedpurpleled
Ventilation unit does not couple correctly with the
support base
Check that the coupling is properly done
Acoustic signal to disable -
Press the button for 7 seconds: a green led
ashes.
TROUBLE SHOOTING
2014/35/UELowVoltageDirective(LVD)and2014/30/UEElectromagneticCompatibility(EMC),inconformitywiththefollowingstandards:
ElectricalSafetyEN60335-1(2012)+A11+A13;EN60335-2-80(2003)+A1+A2.
ElectromagneticCompatibilityEN55014-1(2017);EN55014-2(2015);EN61000-3-2(2014);EN61000-3-3(2013).
STANDARD CONFORMITY
BACKUPBUTTON
Incasetheremotecontrollergetslostorthebatteriesaredead,speeds1,3andOFFpositioncanbeselectedfromtheonboardtouch
button(C).Theairowdirectionisalwaysalternateandtheoperationmode(eithercomfortorefficiency)isthelastselectedfromthe
remote controller.