FUNCTIONALITY DESCRIPTION
CONTROLLER
BUTTON
ICON LED
ACOUSTIC
SIGNAL
Airowdirection
Alternate
The unit runs in extract/intake at the selected speed: the inversion
timeisautomaticallydefinedthankstotheintegreltemperaturesensor
(comfort mode).
green short
Extract Theunitrunsinextractonlyattheselectedspeed. green short
Intake The unit runs in intake only at the selected speed. green short
Mode(activeonlyiftheairowdirectionissetonalternate)
Comfort
Optimisationoftheacousticandthermalcomfort.Theinversiontime
varies automatically from 40÷120 seconds, thanks to the integrel
temperaturesensor.Thefirsttimecycleisof70seconds,thenitvaries
automatically according to the detected temperature conditions.
green short
Efficiency
Optimisationofthethermalefficiency.The inversion time is fixed at
about 70 seconds.
green short
Continuous running speed
Speed 1: 20m
3
/h green short
Speed 2: 30m
3
/h green short
Speed 3: 40m
3
/h green short
Speed 4: 50m
3
/h green short
Speed5:60m
3
/h green short
Offposition
Pressing the button for 3 seconds, the units switches off, emitting a
long acoustic signal. To re-activate the unit, press or .
red long
BOOSTspeed
Theunitrunsatspeed5(maximum)for15minutes,inextractonly;
then it returns to the previously selected mode/speed.The BOOST
speedcannotbeactivatedifthecontrollerisOFF.
fixedblue short
Free cooling
Theunitrunsin“extractonly”or“intakeonly”toavoidheatrecovery
when not needed.
green short
COMFORT
EFFICIENCY
OFF
or
+
+
+
+
+
Filter reset
Every3monthsayellowwarningledswitcheson(fixedlight)toindicate
thatthefiltershavetobemaintained.Pressthededicatedbuttonfor5
seconds to reset the timing.
green short
Smart humidity control
When the humidity sensor detects a quick variation of the Relative
Humiditylevel,therunningspeedautomaticallyincreasestothenext
higherspeed.After10minutesfromthelastquickRHvariation,the
unit returns running at the selected speed. The smart humidity control
isactiveiftheairowdirectionissetonalternateorextractonly:if
speed 5 has been selected, no speed increase happens. To disable this
functionality, press the button for 5 seconds: on the top side of the
LCDdisplaythesymbolisshown.
ashing
blue
Antifrost
Thisfunctionalitypreventsfrostbuildingupontheheatexchangerdue
toextremelycoldair.Whenitisactivated,theunitrunsinextractonly
at speed 1, for 30 minutes.
fixedred
Acoustic signal
Any time a setting is transferred from the controller to the unit, a short
acoustic signal is emitted. This can be deactivated by pressing the cgfgf
buttonfor7seconds,afterwhenagreenledashestoindicatethatthe
acoustic signal is off. To reactivate the acoustic signal repeat the same
operation for 7 seconds until the led becomes green and an acoustic
signal is emitted.
green short
FILTER