aerodynamically optimized interieur with enclosed, non-visible
blower. Highly pressuredrop resistant even with longer and more
complex ductings.
Suitable for ducted or recirculated extraction configuration (incl.
differentiated software modes). Installation accessories for
unducted recirculation, among these four cleanAir odor filters and a
telescopic slider element, are included in the cooktop. Accessories
for other installation options are available, details in the planning
notes.
Easy-to-detach and easy-to-clean grease filter and liquid collector
unit:
Integrated, large-scale, high performance stainless-steel grease
filters with 12 filtration layers and one black top layer for enhanced
aesthetical integration.
All parts of the unit are easy-to-clean, fully dishwasher safe and
heat resistant.
(Upper) Liquid collector unit with 200ml of capacity for standard
accidental spillages or cooking condensate.
Powerful drainage system for spillages that exceed 200ml of liquids.
Liquid safety collector with additional capacity of 700ml for more
severe accidental situations. Dishwasher safe. Easily accessible and
detachable from below.
Overall capturing capacity of 900ml (200ml + 700ml).
Watertight blower system.
Extraction performance in ducted extraction (according to EN
61591): min. normal setting 154 m3/h , max. normal setting 500
m3/h , max. Boost-/Intensive setting 622 m3/h .
Extraction performance in recirculated extraction (according to EN
61591): min. normal setting 132 m3/h , max. normal setting 499
m3/h , max. Boost-/Intensive setting 595 m3/h.
• - Noise level in ducted extraction (Sound power level according to
EN 60704-3): min. normal setting 42 dB re 1 pW, max. normal
setting 69 dB re 1 pW, max. Boost-/Intensive setting 74 dB re 1
pW.
• - Noise level in recirculated extraction (Sound power level according
to EN 60704-3. ): min. normal setting 41 dB re 1 pW, max. normal
setting 68 dB re 1 pW, max. Boost-/Intensive setting 72 dB re 1
pW.
• - Large scale filter surface with high odor reduction capabilities.
• - cleanAir odor filters: Lifetime of 360 hours of cooking
(non-regenerative).
Planning & installation notes
Suitable for ducted or recirculated extraction installations in 4
different options (unducted, partly and fully ducted recirculation or
ducted extraction). Installation accessories for unducted
recirculation, among these four cleanAir odor filters and a telescopic
slider element, are included in the cooktop. The included
accessories allow easy and quick installations and can be planned in
all worktop depths ≥60cm. For other types of installation, one of the
following accessory kits is recommended:
Z861KR0 for partly-ducted recirculation in worktops of 70cm depth
of ≥70cm depth with max. worktop height of 960 mm.
Z861KE1 as starter kit for ducted extraction in worktops of ≥60cm
depth.
To complete the fully ducted extraction or to do any other individual
recirculation planning different ducting accessories are available.
Planning suggestions:
• - Installation is possible in island as well as wall oriented
configurations.
• - The product and its accessories comply with the Needle Flame
Test (according to IEC 60695-11-5) and the B1/B2 building material
class (according to DIN 4102-1).
• - The max. immersion depth is 223mm below glass for top mounted
appliances and 227mm for flush installed appliances.
• - The appliance must be freely accessible from below (i.e. for
accessing the lower liquid safety collector).
• - No false floor is necessary below the cooktop with integrated
downdraft ventilation system. The drawers and/or shelves in the
floor unit must be removable. The backpanel of the floor unit can be
kept - only a cut-out for the air outlet is needed (position and size
can be taken from the installation instructions).
• - Installation kit Z821UD0 for unducted recirculation requires a
vertical aperture of min. 25mm behind the backpanel of the
furniture. Suggested for ideal performance are 50mm.
• - The minimum worktop thickness is 16mm for top mounted and
flush installed appliances with the standard installation system.
Installation in even thinner worktops is also possible with the spare
part: 626792.
• - The overall appliance weight is 26kg - the bearing capacity and
stability, in the case of very thin worktops in particular, must be
supported using suitable substructures. The overall appliance weight
and the worktop manufacturer's structural integrity specifications
are to be taken into account.
• - For partly ducted and unducted recirculation extraction
installations, a return-flow aperture of ≥400cm² is to be respected in
the plinth area. The aperture can be realized via outlet grids, lamella
grids or subtly shortened plinths depending on the assortment of
the kitchen furniture manufacturer.
• - The air outlet on the backside of the appliance can directly be
accessed with a male flat duct element (DN 150).
• - The pressuredrop resistant blower allows longer and more
complex ductings up to 8m with three 90° bows while keeping
sufficient performance.
- In ducted extraction configuration a one-way flap (or backflow
trap) with a maximum opening pressure of 65Pa should be installed.
4 /