Special Function Description
Memory Function
· In the process of heat preservation, lift the pot for 3 minutes (± 1 min) and put it back,
put back the kettle, at this moment the temperature of the water is not lower than the
temperature of the water when the kettle is picked up below 8℃, then return to the heat
preservation. Water temperature below this value returns to standby
Plateau Judgment
· During the boiling process, if the water temperature in the pot is higher than 80C and
less than or equal to 93°C, the temperature does not rise within 15 seconds after
continuous heating or does not rise within 80 seconds after intermittent heating, it is
considered that plateau boiling point is detected.
· If the boiling point value has been obtained through the plateau program (the value
range is [81-93]), the next time the water is boiled, the work will be adjusted according
to the boiling point value, (this design is to prevent boiling water from flying away).
· In the boiling process, the water temperature in the pot is higher than 93°C, and it enters
the false display stage until the temperature is displayed to 100°C.
Temperature Display
· When 81°C - 93°C, if the temperature does not rise after 15 seconds of continuous heating
or 80 seconds of intermittent heating, it is considered that the boiling point has been
reached. If the current boiling function is normal, the work will be finished directly after
the boiling point is judged; (for areas with altitude within this temperature range, the first
boiling point will be finished by boiling point migration, and then the boiling point in this
area will bememorized, and the subsequent boiling point will be changed according to the
boiling point The temperature should be adjusted in advance to prevent flying water).
· Boiling to boiling function: when 93°C -100°C (excluding 93°C, the false display of water
temperature rising stage is displayed, that is, the water temperature rises by 1 degree
every 5 seconds (when the actual temperature is higher than the displayed temperature,
the displayed temperature will be updated to the actual temperature in time, and the false
display timing variable will be re timed); when the boiling point temperature of boiling
water is between 81-93 C, the second boiling water temperature will be at the boiling point
temperature When the actual temperature is higher than the displayed temperature, the
displayed temperature will be updated to the actual temperature in time, and the false
timing variable will be displayed again.
· Boiling Starting function: after heating, the temperature will drop from 100°C to the current
temperature. If the actual temperature is less than 95°C when 100°C is displayed, the false
display will be displayed until the actual temperature (but the actual temperature will be
displayed when the false display temperature is lower than (set temperature - 5°C); if the
current temperature is greater than or equal to 95°C, the set temperature will be displayed
for 10s, and then press 5s for automatic display The dynamic drop is one degree lower than
the actual temperature.