Add Cold Water Midway
· It is forbidden to add cold water during operation;
· If it is detected that the current temperature suddenly drops below - 8'C of the insulation
temperature during the working process, it is considered that cold water has been added
midway.
· If cold water is detected during gap heating, the program adjusts the heating ratio
appropriately according to the dierence.
Protect Function Description
Heating Time Iimit Protection
· If the boiling Starting working time is more than or equal to 16 (± 1) minutes, if the boiling
Starting function is started, the kettle will automatically enter the dechlorination working
state; if the boiling water heat preservation function is started, the buzzer will sound three
times, and the kettle will automatically enter into the heat preservation working state.
Sensor Over Temperature Protection
· Continuously detect that the temperature of the temperature sensor in the kettle is greater
than or equal to 120°C" for 1 s, and the heating pipe stops heating and alarms at the same
time.The nixie tube displays C1 and the buzzer sounds 10 times to enter the failure mode.
Sensor Short Circuit Protection
· IIf the temperature sensor in the pot is short circuited for 0.5s continuously, the heating
tube stops heating and alarms at the same time.The nixie tube displays E2, and the buzzer
beeps all the time and enters the failure mode.
Sensor Open Circuit Protection
· The open circuit of the temperature sensor in the pot is detected for 0.5s .continuously,
and the heating pipe stops heating, and the alarm is given at the same time.
· The nixie tube displays E1 and the buzzer sounds 10 times to enter the failure mode.
Zero Crossing Abnormal Protection
· If abnormal zero crossing signal is detected for 5s, the heating pipe will stop heating and
alarm at the same time.
· The nixie tube displays E0 and the buzzer sounds 10 times to enter the failure mode
Sensor Abnormal Protection
· During the boiling process, the water temperature in the kettle is less than or equal to
80°C, the temperature does not rise by 1°C within 5 minutes (± 20s), the heating tube
stops heating, and the alarm is given at the same time.The nixie tube displays E7 and the
buzzer sounds 10 times to enter the failure mode.