AC Switching Characteriscs
Data Sheet
© 2024 Microchip Technology Inc. and its subsidiaries
DS00003831E - 39
–1 speed grade is oered for Extended Commercial (E), Industrial (I), and Automotive (T2)
temperature grades only.
Table 5-15. Global and Regional Clock Characteriscs (–55 °C to 125 °C)
Parameter Symbol V
DD
= 1.0V
STD
V
DD
= 1.0V
–1
V
DD
= 1.05V
STD
V
DD
= 1.05V
–1
Unit Condition
Global clock F
MAX
F
MAXG
500 500 500 500 MHz
Regional clock F
MAX
F
MAXR
375 375 375 375 MHz Transceiver interfaces only
F
MAXR
250 250 250 250 MHz All other interfaces
Global clock duty cycle
distortion
T
DCDG
190 190 190 190 ps At 500 MHz
Regional clock duty cycle
distortion
T
DCDR
120 120 120 120 ps At 250 MHz
The following table describes clocking specications from –40 °C to 100 °C.
–STD speed grade is oered for Extended Commercial (E), Industrial (I), Military (M), and Automotive
(T2) temperature grades.
–1 speed grade is oered for Extended Commercial (E), Industrial (I), and Automotive (T2)
temperature grades only.
Table 5-16. High-Speed I/O Clock Characteriscs (–55 °C to 125 °C)
Parameter Symbol V
DD
= 1.0V
STD
V
DD
= 1.0V
–1
V
DD
= 1.05V
STD
V
DD
= 1.05V
–1
Unit Condition
High-speed
I/O clock F
MAX
F
MAXB
1000 1250 1000 1250 MHz HSIO and
GPIO
High-speed
I/O clock
skew
1
F
SKEWB
30 20 30 20 ps HSIO without
bridging
F
SKEWB
See note 3 ps HSIO with
bridging
F
SKEWB
45 35 45 35 ps GPIO without
bridging
F
SKEWB
75 60 75 60 ps GPIO with
bridging
High-speed
I/O clock duty
cycle
distortion
2
T
DCB
90 90 90 90 ps HSIO without
bridging
T
DCB
115 115 115 115 ps HSIO with
bridging
T
DCB
90 90 90 90 ps GPIO without
bridging
T
DCB
115 115 115 115 ps GPIO with
bridging
1. F
SKEWB
is the worst-case clock-tree skew observable between sequential I/O elements. Clock-tree
skew is signicantly smaller at I/O registers close to each other because they are fed by the same
or adjacent clock-tree branches. Use the Libero SmartTime Timing Analyzer tool to evaluate clock
skew specic to the design.
2. Parameters listed in this table correspond to the worst-case duty cycle distortion observable at
the I/O ip ops. IBIS should be used to calculate any additional duty cycle distortion that might
be caused by asymmetrical rise/fall times for any I/O standard.