Vega TP-3 Operating Manual Page 13
4.2.5 Volts Setup
Mode:
Select the function for the analog channel. Options are “PRESSURE”, “TEMP”, “CURRENT”, “VOLTS” or “OFF”.
Label:
Enter a label to suit your volts channel so you can identify it easily.
Display Max:
Select the maximum value that you want the volts bargraph to show. This can give you increased display resolution.
Display Min:
Select the minimum value that you want the volts bargraph to show. This can give you increased display resolution.
High Alarm:
This enables or disables the volts high alarm.
High Alarm:
Enter the voltage threshold for when the high alarm must be activated. Any voltage above this value will activate the
alarm.
High Caution:
Enter the voltage for the high caution. This is the lower value of the upper yellow band.
Low Caution:
Enter the voltage for the low caution. This is the upper value of the lower yellow band.
Low Alarm:
This enables or disables the volts low alarm.
Low Alarm:
Enter the voltage threshold for when the low alarm must be activated. Any voltage below this value will activate the alarm.
Cal:
Measure the battery voltage with a multimeter and then adjust this value to match that of the multimeters volts reading.