Vega TP-3 Operating Manual Page 12
Zero Sensor:
Select this function to indicate to the TP-3 that zero current is flowing through the MGL
Avionics Closed Loop Current sensor. This is best done with the MGL Closed Loop
Current sensor disconnected from the main current supplying conductor.
Gain:
Adjust the gain factor until the current is reading correctly. It will be best if a multimeter can be inserted in series with the
current supplying conductor and the gain calibration adjusted until the TP-3 matches that of the multimeter. Please see
the MGL Avionics Closed Loop Current Sensor documentation for more information.
Data:
Select the data source of the current signal. Options include internal (using one of the analog channels within the TP-3) or
from an optional external RDAC unit.
RDAC Address:
Select the CAN address of the RDAC unit.