Testing using the PAT250SX
6.5 Class 1 test using mains voltage leakage @ 230 V AC
Mains powered testing of equipment with an Earth return conductor
1. Plug the appliance
under test into the
PAT
2. Plug the PAT
tester into a
power supply
3. Connect BOND
lead P1 to a metal
point on the
appliance
4. Turn on the
appliance
under test
5. Select required voltage
6. Ensure probe P1
connected
Class 1 @ 500 V OR Class 1 @ 250 V
for IT equipment
7. See note 1 8. See notes 1, 2 and 3
below
9. Warning: Appliance will operate. If the appears,
check appliance is switched on and press
.
Before the test starts the
GandF will flash warning
that the appliance will operate, press the
to
proceed.
10. Class 1 Pass
NOTE : 1: If the contact symbol appears, the appliance needs to be switched ON.
The PAT250SX performs various pre-checks prior to testing to ensure the asset is not short-circuit and is switched on
NOTE : 2: If the L to N short circuit symbol shows, user must check whether there is a true short circuit.
Press Class 1 button to proceed but there is a risk of damage or tripping of protective devices. If the L-N or
L-E symbol is flashing a low resistance has been detected. An L-E fault will stop the test. See Measurement
symbols table. An L-N fault could damage the PAT tester and should be investigated. To override an L-N
warning, press the Class 1 button.
NOTE : 3 : Faulty equipment may cause an RCD to trip during a Touch leakage test
WARNING : High inertia appliances (e.g. angle grinders) may present a hazard whilst running. It is
recommended that where a hazard is likely, the battery powered “Substitute leakage” test is used, which
will not operate the appliance

Bekijk gratis de handleiding van Megger PAT250, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkMegger
ModelPAT250
CategorieNiet gecategoriseerd
TaalNederlands
Grootte7085 MB