Technical Manual Presence Detector SCN-x360xx.03
MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 • Germany
Telephone: +49-2263-880 • knx@mdt.de • www.mdt.de
34
34
Fully automatic with orientation light:
Figure 24: Process diagram – Fully automatic with orientation light
The operating mode "fully automatic with orientation light" extends the operating mode fully
automatic by the status orientation light. The orientation light can be activated as soon as the
"Object type for output - light" parameter is set to absolute dimming.
The orientation light is switched on as soon as the follow-up time of the light channel has elapsed.
The output is then switched to the orientation light state and can therefore dim the light to a darker
level in order to leave the room safely.