8/22 Rev. R 132617 ©2022 Refrigerated Solutions Group. All rights reserved.
WALK-IN INSTALLATION
SITE SELECTION, BASE PREPARATION
WALK-IN COOLER OR FREEZER WITHOUT A FLOOR INSTALLED ON FOAMED SEALERS
IMPORTANT! Do not attempt to erect a floorless walk-in FREEZER on an existing building floor that has not been
specially prepared and adequately insulated for below freezing storage temperatures. Note: All thermal breaks
in floor slab must be exposed, including the partition wall. To install a foamed sealer (screed) assembly on an
existing floor, or on a properly prepared floor for freezers, proceed as follows:
Locate the floor sealer (screed) diagram that was packed in the hardware box and, using it as a guide, draw a properly
dimensioned outline of the sealer (screed) assembly directly onto the building floor precisely where the walk-in will
be situated. These lines will be the same dimensions as the dimensions of the walk-in in both directions. If the walk-
in is to be installed next to an existing building wall(s), make sure that a MINIMUM OF 2” REMAINS BETWEEN
THE DRAWN OUTLINE AND THE BUILDING WALL(S). This space will allow for irregularities in the building wall(s)
and will permit a free flow of air between the two surfaces. CAREFULLY CHECK FOR SQUARENESS by confirming
that the dimensions between opposite corners are equal (Figure 1).
Since the foamed sealer (screed) is retained in position by a 3/8” thick plywood sealer guide, which will be secured
to the building floor, it is imperative that the sealer guide be accurately located, as well, on the building floor. Refer
to the sealer guide diagram which was also packed in the hardware box. On the diagram, you will notice that the
sealer guide is located 7/8” INSIDE the drawn outline which represents the outside dimensions of the sealer (screed)
assembly. Further, Fig. 1 illustrates that the sealer guide is 2 1/4” wide centered beneath a 4” wide sealer leaving a
border of 7/8” along each edge. Draw another outline of the outside dimensions of the sealer guide directly onto
the floor. There should be exactly 7/8” between the new sealer guide outline and the previously drawn sealer (screed)
outline (Figure 2, on next page).