Status LEDs and Test/Reset button
Status information
P3 PowerPort devices give status information via LEDs on their front panels. A key to the status
information given by the LEDs is printed on the device and given below.
For each output:
• The Data LED lights when data is being transmitted at that output.
• The Power LED lights when 48 VDC power is present at that output.
• NET1 and NET2 LEDs light to indicate traffic at the corresponding network data port.
• The LED gives the information in the table below:
Color
Output
Indication
Suggested action
Blue
Constant
Busy (e.g. booting up or writing to
flash memory).
Wait a moment for normal
operation to be resumed.
Green
Constant
P3 protocol detected.
Magenta
Constant
Art-Net or sACN detected.
Red
Flashing
No control source detected (no
protocol detected on Ethernet).
Connect a P3 System Controller,
Art-Net controller or sACN
controller to the network.
Yellow
Constant
Overtemperature.
Allow the device to cool. Clean
the device and improve
ventilation. Press Test/Reset
button to restore functionality.
Red
Constant
Error. The P3 PowerPort has
encountered a fatal error and
cannot run.
Perform a factory reboot. If the
problem persists, carry out a
firmware upload.
Fast RGB
Cycling
Test pattern being sent to
connected products.
Test/Reset button functions
P3 PowerPort devices have test sequences stored in internal memory that you can call up using the
Test/Reset button. The test sequences let you check that the connected creative LED products are set up
correctly without the need for a controller. Note that test patterns can also be called up on P3 system
controllers and on any individual system components that have a test/control button.
The Test/Reset button also lets you reboot the device and restore its factory default firmware if you
suspect that the firmware has been corrupted.
If an output on a P3 PowerPort has been disabled because of an overload or short circuit, pressing the
Test/Reset button will re-enable the output.
The functions of the P3 PowerPort’s single Test/Reset button are printed on the device and given below:
Button action
Function
Repeated short press
Display the following test patterns on all Martin Creative LED
display products that are correctly connected (one short press
scrolls to next pattern): Calibrated mixed White → Full Red → Full
Green → Full Blue → Full White
Press and hold until status
LED lights blue
Reboot the P3 PowerPort.
Press and hold until status
LED lights white
Return the P3 PowerPort to its default factory firmware.