Physical installation 13
Avoiding damage when installing
Avoid causing damage that is not covered by the product warranty by following these instructions carefully.
Keeping connections dry
Moisture on connectors can cause short circuits and damage to products. Check that all connectors are
perfectly dry before you connect them. Do not install the Exterior PixLine during wet weather conditions or if
condensation is visible on any surfaces.
Avoiding shocks and stress
Do not expose the Exterior PixLine to physical shocks (by dropping onto a hard surface, for example).
Do not apply pressure to or otherwise stress diffusers or lenses.
Do not stress cables (by bending them sharply, for example). Protect cables from sharp edges.
Protection from corrosion
Fixtures and profiles are manufactured in corrosion-resistant anodized aluminum, but you must take
precautions to avoid direct contact between aluminum and other metals, as this can cause galvanic
corrosion:
• Use an electrically insulating material (such as rubber or plastic) or a coating between aluminum fixtures
or mounting profiles and any other metal.
• Use a non-conductive coating such as Delta Seal on fasteners (screws, bolts, washers, etc.) where they
come into contact with fixtures or mounting profiles.
Thermal expansion, end-to-end gaps and pixel pitch
In indoor locations at room temperature and similar locations where Exterior PixLine fixtures are subject to
minimal temperature variations only, it is not necessary to leave end-to-end gaps between Exterior PixLine
10 fixtures to allow for thermal expansion, but you must still leave a gap of approximately 10 mm between
Exterior PixLine 20 and Exterior PixLine 40 fixtures if you want to maintain a uniform pixel pitch. If
maintaining exact pixel pitch is important, adjust the position of fixtures until the end-to-end gaps give the
most even pixel pitch.
To avoid damage to fixtures from thermal expansion and obtain the best visual results, follow these
instructions carefully:
Exterior PixLine 20 and 40
Exterior PixLine 20 and Exterior PixLine 40 standard length fixtures are 310 mm or 1270 mm long.
• In all locations, allow a space for each fixture that consists of the nominal length of the fixture (310 mm,
1270 mm or a custom length) plus 10 mm. If you are installing 310 mm Exterior PixLine 20 or Exterior
PixLine 40 fixtures end-to-end, for example, you must install them with 320 mm between the left-hand
ends of the fixtures as shown in Figure 3.
Setting up gaps by this method will give the most even pixel pitch in a line of fixtures while allowing
suitable gaps for thermal expansion. This method will also allow for production tolerances. An Exterior
PixLine fixture can be up to 5 mm longer than its nominal length, so the actual end gaps will be between
5 mm and 10 mm.
310 mm fixture 310 mm fixture 310 mm fixture
320 mm space
320 mm space
320 mm space
Figure 3: Method of spacing for thermal expansion