Martin Audio iK41 handleiding

61 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 38 van 61
Keep your amplifier away from dirt,
liquids and vapour from theatrical smoke
and fog machines.
Damage from these sources isn't
covered by the warranty.
AC power connection
The amplifier uses a 32A Neutrik powerCON locking AC
power connector. You must use an AC power cable with
the correct powerCON connector.
The amplifiers are designed to operate on 50/60 Hz AC
power. The power supply sections automatically configure
themselves for either 100120 V or 220240 V nominal
voltage at start up. The amplifiers will operate over an
extended range of supply voltage with thresholds as
follows:
100120 V range thresholds 75138 V
220240 V range thresholds 138275 V
Note that whilst the amplifier will operate correctly at
the voltages indicated, the specified output power will
only be achieved when operating with the stated nominal
voltages.
Once an amplifier has configured itself for a particular
range it will not change range, even if the mains voltage
varies wildly, unless the power is completely interrupted
for several seconds or is cycled by the user.
During start up the amplifier checks the mains
environment and waits for the mains to settle within either
the 100120 V or 220240 V ranges. If the mains takes
a long time to settle, the amplifier will display one of the
following messages on the front panel:
Message Problem
Mains too low Voltage below the 100120 V range threshold of
75 V
Mains too high Voltage above the 220240 V range threshold of
275 V
Mains unstable Voltage within the 100120 V or 220240 V range
but is unstable
When an amplifier is running normally, it continuously
monitors the mains to ensure that it remains within the
initially selected range. If the mains voltage is outside
that range the amplifier will enter protection mode and
briefly display the message Mains out of range followed
by one of the messages above. In protection mode, audio
will be muted but communication with the amplifier will
still be possible. The amplifier will continue to monitor the
mains and will automatically resume normal operation if
the mains is stable and has returned to the initial range
selected when the unit was first powered up.