RCP-PLUS User Manual
Chapter 5: Assigning Cameras via IP
Now that the RCP-PLUS is connected to the local IP network (section 4.1 above),camerascanbeassigned
to control buttons and labeled.
Press and release an available square button (2 seconds). The camera add page will appear.
TAP the VISCA over IP button.Themessage“Searching Visca IP” will appear for a moment.
An IP address will appear in a window. When more than one IP camera
isonthenetwork,taptheaddresstoseealistofallcameraaddresses.
Choose the address of the camera that is to be assigned by sliding up or
down on the list to highlight the desired camera.
Tap Choose to select a camera or Cancel to start again.
Step 1. Press Select Camera Model
Select the camera model number that most closely matches the Marshall camera that is connected. For
example: select CV37*/CV57* when using model CV374.
Note: Selecting Universal is only recommended for 3rd party products. The RCP-PLUS can control
only functions that exist in the attached camera even though that function may appear as a choice
on the display.
Step 2. TheRCP-PLUSnamestherstcamerabuttonlabelas“1.Ifthecamerawillbereferredtoas
someothernumberduringliveproduction,thelabelonthebuttonmaybechangedtoanumberorletter
asdesired.PressRCPLabel,turntheleftknobclockwisefornumbers,counterclockwiseforletters.
Step 3. Press Camera ID,turntherightknobtosettheIDnumbertomatchtheIDnumberthatissetin
thecamera.WithVisca,eachcameramuchhaveauniqueIDnumberfrom1 – 7. It is important that this
number matches the Visca ID number set in the camera.
Step 4. Press Select Output Format to set the desired Output Format and Frame Rate.
Step 5. Press Apply to make all changes active. The display will change to the White Balance page (WB
is highlighted) and is ready for use.
Conrmation: AquickcheckcanbeperformedbypressingtheOSDbutton,thenpressOn. The camera’s
on-screen menus should appear in the camera’s video output. Press On again once or twice to clear the
menu display.
Ifthisquickcheckworked,everythingisOKandnormaloperationcanbeginbyselectingthedesired
functionfromtherightsideofthescreen(WhiteBalance,Exposure,etc.).
Ifthequickcheckdidnotwork,checkallconnections,conrmthatthevideobeingmonitoredisfromthe
camera being controlled.
Chapter 6: Web Browser Operation
ToaccesstheRCP-PLUSviaawebbrowser,simplyentertheRCPIPaddressintoabrowserwindow(Firefox
works reliably). The log-in screen will appear. Enter the Username admin and the password 9999.
A pop-up window allows changing the password and ID at this point or select Not Now to move on.
The Web Browser interface is provided as an assistant to simplify two setup functions:
- Set a Static IP address in the RCP-PLUS
- Quickly assign IP cameras to the RCP-PLUS
The Web Browser interface does not assist with an RS485 connection and it does not provide camera
control functions. Its purpose is quite simple.
6.2 Setting a Static address.
Step 1. Select the Network tab at the top of the page.
Step 2. CheckthattheDHCPbuttonistotheleftwhichmeansDHCPmodeOFF,StaticmodeON.
Step 3. EnterthedesiredIP,GatewayandSubnetMaskintotheeldsprovided.
Step 4. Click the Submit button. Done!
The Web Browser interface will restart with the new address.
6.3 Assigning an IP Camera to a button “label” on the RCP-PLUS
Step 1. Select Camera tab at the top of the page.
Step 2. Click on the Search button. IP cameras on the local network will be listed.
Step 3. Clickonthe“+”nexttoaCameraIPaddress.Ablueiconwillappearonthepage.
6.1 Logging in