2.5 Connecting the wiring
After the entire floor area has been covered with heating foil, the wiring can be connected. On the side
where no connecting wires are connected, you must cover all copper conductors with insulating tape.
Pay attention! Take a good look at the laying schedule below. This diagram shows how the wiring must
be connected in parallel between the strips of heating film. Take a good look at how the blue and black
wiring is laid.
1. Pierce a hole in the copper foil with an eyelet punch.
2. Push the pressed terminal into the slot between the copper foil and silver booth bar.
3. Place an eyelet terminal on the pressed terminal.
4. Strip the wire with a stripper and put the wire in the eye of the pressed terminal.
5. Use the wire presser to flatten the eyelet terminal and pressed terminal so that the power wire is
fixed to the heating film. Test that the wiring is making good contact and is firmly attached to the
connector.
6. Use the insulating tape and stick it over the flattened pressed terminals and eyelet terminals with
wiring. PAY ATTENTION! The tape must extend at least 5 mm over the end of the connection and
cover all live parts.