F-6
DIAGRAMS
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted
inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.
A.06
230VAC, 1~,50Hz
N
2
24V
2A
1A1A
C C
OL
A2
FAN ON/OFF
N
24V
FAN MANUAL
ON/OFF
ARC
SENSOR
FLOOD
LIGHT
C
OL
SET TO 5.75A
BK
BK
FAN
MOTOR
230VAC, 1~,50Hz, 1HP
L
N
S1
S2
S3
SCHEMATIC
1 3
4 5
6
10
GND
CONTROL BOX
L
GND
CONNECT GND
TO TERMINAL
N
205
204B
L1
L2
L3
A113
CONTACTOR
OVERLOAD
RELAY
SET AT 5.75A
T1
T2
T3
A2
1
3
TRANSFORMER
N
24V
2A
WH
BK
RD
3 CONDUCTOR CABLE,
PROVIDED 20AWG
ARC SENSOR
WH
BL
RD
BK
BK
WH
CONN-PCB
YE/GN
MOTOR
GND
FAN MOTOR
S1
S2
S3
START
CAPACITOR
230VAC, 1~, 50Hz, 1HP
201
202
202
201
4
5
207
206
NA
205
203
209
203
207
204A
204B
209
WIRING
3 CORE 16AWG CABLE
20AWG
3 CORE CABLE
N
L
N
L
Z2
U2
V2
U1
V1
Z1
BK
RD
2
6
10
N B.
N B.
DISCONNECTING MEANS AND BRANCH CIRCUIT
PROTECTION SHALL BE PROVIDED BY THE INSTALLER
208
MOTOR LAMP CONTROLLER PRISM 2400, 230V, 1~, 50Hz, 1HP
NOTES:
N A. MOUNTING ON DIN RAIL
N B. FIELD WIRING SHALL USE UL RATED 3C MIN 16AWG CABLE
WITH OUTER DIA BETWEEN 0.27 TO 0.51 (7MM TO 13MM)
N C. 201,202,208 SHALL BE BLACK AND 14AWG