Handleiding
Je bekijkt pagina 8 van 20

8
www.lavorwash.com.au
LAVOR - IFH-175
USER MANUAL
175,000BTU - Industrial Fan Forced Heater
OPERATION
FUEL GUIDELINES
• For optimal performance, only use Diesel Fuel or 1-K kerosene in this heater. 1-K kerosene is rened
to virtually eliminate contaminants such as sulfur, which can cause unpleasant odors, like a rotten egg smell,
during operation.
• Be aware that alternative fuels do not burn as cleanly as 1-K kerosene. If alternative fuels are used, ensure
adequate fresh air ventilation to oset any additional contaminants introduced into the heated space.
Note: Kerosene should be stored only in a blue container marked “kerosene.” Never store kerosene in a red
container, as red signies gasoline.
• NEVER store kerosene inside a living space. Store it in a well-ventilated area outside the living area.
• NEVER use volatile fuels such as gasoline, benzene, alcohol, white gas, camp stove fuel, paint thinners, or other
oil compounds in this heater. These fuels are highly ammable and could cause a re or explosion.
• NEVER store kerosene in direct sunlight or near heat sources.
• NEVER use kerosene that has been stored from one season to the next, as kerosene deteriorates over time.
Old kerosene will not burn properly in this heater.
OVERVIEW OF HEATER DESIGN
Fuel System:
• This heater is equipped with an electric air pump that forces air through an air line connected to the fuel intake,
and then through a nozzle in the burner head. When air ows in front of the fuel intake, it causes fuel to rise from
the tank and spray into the burner nozzle.
• The air and fuel mixture is then atomized into a ne mist and sprayed into the combustion chamber.
SureFire Ignition System:
• An electronic ignitor sends voltage to a specialized spark plug, which ignites the fuel-air mixture in the combustion
chamber.
Air System:
• A heavy-duty motor powers a fan that forces air into and around the combustion chamber. The air is heated
and released from the front of the heater, creating a steady ow of warm air.
THE SAFETY SYSTEM
Temperature Limit Control:
This heater includes a Temperature Limit Control to automatically turn o the heater if the internal temperature rises
to an unsafe level.
If the control activates and shuts o your heater, it may require servicing.
Once the temperature falls below the reset threshold, you can restart the heater.
Bekijk gratis de handleiding van Lavor IFH-175, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Lavor |
Model | IFH-175 |
Categorie | Heater |
Taal | Nederlands |
Grootte | 4061 MB |