VS-8FDxl - Protocol 3000
42
PRST-LOCK
Functions
Permission
Transparency
Set:
PRST-LOCK
End User
Public
Get:
PRST-LOCK?
End User
Public
Description
Syntax
Set:
Set a preset as read-only
#PRST-LOCKSPpreset_Index,modeCR LF
Get:
Get the preset read-only status
#PRST-LOCK?SPpreset_IndexCR LF
Response
Set / Get: ~nn@PRST-LOCKSPpreset_Index,modeCR LF
Parameters
preset_Index – 1 to 8 (preset number)
mode – ON, OFF
Notes
Prevents users from overriding the preset by mistake
Examples
#PRST-LOCK? 1
~01@PRST-LOCK 1,OFF
#PRST-LOCK? 2
~01@PRST-LOCK 2,OFF
#PRST-LOCK 2,ON
~01@PRST-LOCK 2,ON
#PRST-LOCK? 2
~01@PRST-LOCK 2,ON
K-Config Example
Set preset 1 as read only:
“#PRST-LOCK 1,ON”,0x0D
PRST-STO
Functions
Permission
Transparency
Set:
PRST-STO
End User
Public
Get
-
-
-
Description
Syntax
Set:
Store current connections,
volumes and modes in preset
#PRST-STOSPpresetCR
Get:
-
-
Response
~nn@PRST-STOSPpresetCR LF
Parameters
preset – preset number: 1 (Port 1)… 8 (Port 8)
K-Config Example
Store preset 1:
“#PRST-STO 1”,0x0D