Kramer Electronics Ltd.
PT‑2C – Connecting the PT‑2C
7
EDID loading/storing
The EDID DIP-switch 1 determines the behavior of EDID on the device.
The Pass-through Mode
In the pass-through mode (DIP-switch 1 set to on), the EDID of the connected output (a
display in the following examples) is automatically loaded to the PT‑2C.
If the display is replaced, the PT‑2C captures the new EDID from the new display. Any
change in the output automatically changes the EDID that is stored in the
PT‑2C.
When disconnecting the output, the last EDID remains stored in the PT‑2C.
The EDID Lock Mode
When in the Lock mode (DIP-switch 1 set to off), the current EDID is locked and remains
unchanged even if the display is replaced on the output.
When in the lock mode the audio setup is determined by the DIP-switch 3 Audio setup.
You can connect a PC to the EDID DESIGNER/F/W UPDATE Mini USB port to modify the
EDID via the Kramer EDID designer software.
Note that when using EDID designer to modify the EDID (in the Lock mode), the DIP-switch
3 status is ignored.
Setting the default EDID
You can set the PT‑2C to its EDID default value.
To set the default EDID:
1. Make sure the PT‑2C is set to the Pass-through mode
2. Disconnect the output.
3. Set DIP-switch 1 to the Lock mode (off).
The default EDID is loaded