Selecting PV inputs
If the inverter's DC inputs are not fully occupied, distrib-
ute the input assignment according to the following
tables:
PIKO CI U
DC,max
I
MPP,max
I
String,max
30 ≤ 1000 V ≤ 37.5 A ≤ 14 A
50/60 ≤ 1000 V ≤ 33.0 A ≤ 14 A
PIKO CI
Connected
PV strings
MPP tracker
1 2
Used DC input
30
1 1...6
2 1 4
3 1, 2 4
4 1, 2 4, 5
5 1, 2, 3* 4, 5
6 1, 2, 3* 4, 5, 6*
* only with I
Strings,max
≤ 12,5 A per DC input
PIKO CI
Connected
PV strings
MPP tracker
1 2 3 4
Used DC input
50/60
1 2...10/12
2 2 6
3 2 6 10
4 2 6 10 13
5 2, 3 6 10 13
6 2, 3 6, 7 10 13
7 2, 3 6, 7 10, 11 13
8 2, 3 6, 7 10, 11 13, 14
9 2, 3, 4* 6, 7 10, 11 13, 14
10 2, 3, 4* 6, 7, 8* 10, 11 13, 14
60
11 2, 3, 4* 6, 7, 8* 9,10, 11* 13, 14
12 2, 3, 4* 6, 7, 8* 9,10, 11* 12, 13, 14*
* only with I
Strings,max
≤ 11 A per DC input
INFO
Only connect PV modules of the
same type to a MPP tracker, i.e.
n same manufacturer,
n same type,
n same power,
n same size.
3
2
3
4
5
6
7
8
9
10
1