Step 3: Drill Wall Hole
A hole in the wall should be drilled for refrigerant piping, the drainage pipe and connecting
cables.
1. Determine the location of wall hole base on the position of mounting plate.
2. The hole should have a 70mm diameter at least and a small oblique angle to
facilitate drainage.
3. Drill the wall hole with 70mm core drill and with small oblique angle lower than the
indoor end about 5mm to 10mm.
4. Place the wall sleeve and wall sleeve cover (both are optional parts) to protect the
connection parts.
Caution: When drilling the wall hole, ensure to avoid wires, plumbing and other sensitive
components.
Step 4: Connecting Refrigerant Pipe
1. According to the wall hole position, select the appropriate piping mode. There are
three optional piping modes for indoor units (as shown in the illustration on the
next page):
In Piping Mode 1 or Piping Mode 3, a notch should be made by using scissors
to cut the plastic sheet of piping outlet and cable outlet on the corresponding
side of the indoor unit.
Outdoor
Small oblique
angle
Wall sleeve
(Optional)
Indoor
5-10mm
Wall sleeve Cover
(Optional)
Note: When cutting off the plastic sheet at the outlet, the cut should be trimmed to
smooth.