Handleiding
Je bekijkt pagina 20 van 28

Gas Connection
■ A full operational test and a test for possible leakages must be carried out by the
fitter after installation.
■ Access to the whole length of the connection hose must be possible and the gas
hose must be replaced before its use before the end of service life (indicated on
the hose.)
■ Before Leaving-Check all connections for gas leaks with soap and water.
■ DO NOT use a naked flame for detecting leaks. Ignite all burners both individually
and concurrently to ensure correct operation of gas valves, burners and ignition.
Turn gas taps to low flame position and observe stability of the flame for each
burner individually and all together. Adhere the duplicate data plate to an
accessible location near the hotplate. When satisfied with the hotplate, please
instruct the user on the correct method of operation. In case the appliance fails
to operate correctly after all checks have been carried out, refer to the auth
orised service provider in your area.
Ŷ)OH[LEOH+RVH,ILQVWDOOLQJZLWKDKRVHDVVHPEO\LWPXVWFRPSO\ZLWK$61=6
1869,10mmID, class B or D,no more than 1.2m long and installed in accordance
ZLWK$61=6
Ŷ(QVXUHWKDWWKHKRVHGRHVQRWFRQWDFWWKHKRWVXUIDFHVRIWKHKRWSODWHRYHQGLVK-
washer or any other appliance that may be installed underneath or next to the
hotplate.The hose should not be subjected to abrasion, kinking or permanent
deformation and should be able to be inspected along its entire length with the
cooktop in the installed position. Unions compatible with the hose fittings must
be used and all connections tested for gas leaks.The supply connection point
shall be accessible with the appliance installed.
Ŷ:$51,1*(QVXUHWKDWWKHKRVHDVVHPEO\LVUHVWUDLQHGIURPDFFLGHQWDOFRQWDFW
with the flue outlet of an underbench oven.
Natural Gas Regulator
20
Gas Connection
Install in accordance with relevant gas standards and/or
codes of practice applicable.
Connect the elbow fitting to the appliance gas manifold
connection, and check that seals between the elbow and
manifold connection are in place and in good condition.
For Natural gas: connect the natural gas appliance
regulator (pictured opposite) with integral test point using
approved gas thread tape or compound to the elbow
fitting.
Ensure the supply connection point, test point and
natural gas regulator adjustment screw (for Natural gas
installation) are accessible for testing and/or adjustment
with the hotplate in the installed position.