Gas Connection
Inlet connection region for flexiblehose
Where a flexible hose assembly is used, ensur
e it is
approved to AS/NZS 1869, Class B. Any hose assembly
used must be restrained from accidental contact with
the flue outlet of an under bench oven.
This hose assembly shall be suitable for connection to a
fixed consumer piping outlet located as follows:
Hotplates at a point 800 mm to 850 mm above the floor
and in the region outside the width of the appliance to a
distance of 250 mm.
After connecting to gas, check for leaks using soapy
solution, never a naked flame.
Gas Specification
Wok burner Rapid burner
Semi-rapid
Auxiliary
Heat input and orifice size marked (mm)
Gas type &
pressure
10.8MJ/h
6.3MJ/h 4.3MJ/h
0.90 0.68
0.58
1.50
1.15 0.93
13.5MJ/h
1.00
1.72
Natural Gas
1.0kPa
Universal
LP Gas
2.75kPa
WARNING: THE BURNER FLAME MUST BE ADJUSTED BY THE INSTALLER. FAULTY INSTALLATION
IS NOT COVERED BY THE MANUFACTURER’S WARRANTY.