Jung FMGCR1700 handleiding
Handleiding
Je bekijkt pagina 51 van 94

can only be deleted either by reset-
ting to the factory settings or by us-
ing the eNet server. A new position
can be saved at any time, however.
If a blind actuator receives a scene
command without a blind position
having been saved beforehand, the
actuator outputs switch off.
Heating system control
Centralised control of the heating
system is possible via direct opera-
tion in the eNet app, via rules or via
SMART HOME scenes for individual
rooms, individual floors or for the
entire system. The mode (automat-
ic, manual, frost protection) and, in
manual operation, the duration can
be specified.
5. MORE FUNCTIONS
There are more special functions,
which are internally based on the
scenes’ mechanism, in the eNet
system. These enable control op-
erations based on thresholds or
priorities.
• Threshold functions
– Sun protection function
– Twilight function
• Wind alarm
• Lock-out protection
• Restraint
These functions can act on indi-
vidual or multiple actuators. The
lock-out protection function can
be created locally for the balcony
and patio door, for example. The
wind alarm applies globally to all
the outside blinds in the house.
Threshold functions
The threshold functions are trig-
gered when a limit exceeds or falls
below a certain value and call up
appropriate actions. Examples of
threshold functions include the sun
protection function, which causes
the roller shutters to move into a
sun protection position, or the twi-
light function, which lowers the
roller shutters to provide privacy
and switches on the light at the
same time.
Threshold functions are created
in pairs; in other words, they are
made up of two individual scenes.
The first one is called up when a
value exceeds the set threshold,
and the second one is called up
when a value falls below the set
threshold.
Blocking functions
Blocking functions are also created
in pairs and are always connected
to a priority that interferes with
the “normal” functions. A blocking
function is valid until it is cancelled
again or another higher-priority
command is received. During this
time, normal operating functions
or scenes are not executed.
If a blocking scene is cancelled, the
behaviour during cancellation can
be pre-defined. Switching and dim-
ming actuators can switch on or
off, and blind actuators can power
up or shut down. Alternatively, the
state prior to the blocking function
can be restored. In other words, if
no action is performed in the ba-
sic setting, the current state when
the blocking function is cancelled
is retained.
Examples of blocking scenes in-
clude the wind alarm and lock-out
protection.
Restraint
The “Restraint” function is also
used to implement priority con-
trols. Unlike with individual scenes,
the actuator does not access a
saved state (target value); instead,
the sensor also transmits the de-
sired state.
When a restraint command is re-
ceived, the actuator adjusts its out-
put according to the received value
and blocks its control hierarchy
accordingly for other operations.
6. “SCENES FOR SIGNAL
CONTACTS” OPERATING
MODE
In addition to the “Scenes” oper-
ating mode, eNet universal trans-
mitters also have a “Scenes for
signal contacts” operating mode.
Unlike with eNet hand-held and
wall transmitters, here the input
signal is not simply pressing a but-
ton or rocker, but rather the closing
and opening of an electric signal
contact.
Examples of such signal contacts
include outputs on electronic tim-
ers, motion detectors, wind sen-
sors, leakage sensors, thermo-
stats or window contacts.
When the contact is closed, the
eNet transmitter can call up a set
threshold or blocking function,
which it then resets when the con-
tact is opened again.
Examples: Wind alarm for blinds,
blocking function for fan heaters
when windows are open, etc.
If this scene is configured for “app
use”, it is possible to call up one
smart home scene in the app when
closing the contact, and another
one when opening it.
103102 eNet _ Scenes