8.0 Electrical Connections
Electrical connections must be
made by a qualified electrician in compliance
with all relevant codes. This machine must be
properly grounded to help prevent electrical
shock and possible fatal injury.
Before connecting to power source, be sure OFF
button is pressed.
It is recommended that the jointer be connected to
a dedicated 20-amp circuit with a 20-amp circuit
breaker or time-delay fuse marked “D”. Local
codes take precedence over recommendations.
8.1 Grounding Instructions
This machine must be grounded. In the event of a
malfunction or breakdown, grounding provides a
path of least resistance for electric current to reduce
the risk of electric shock. This tool is equipped with
an electric cord having an equipment-grounding
conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
Do not modify the plug provided - if it will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation that is green, with or
without yellow stripes, is the equipment-grounding
conductor. If repair or replacement of the electric
cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal.
Check with a qualified
electrician or service person if the grounding
instructions are not completely understood, or if
in doubt as to whether the machine is properly
grounded. Failure to comply may cause serious
or fatal injury.
8.2 230 Volt Operation
Referring to Figures 8-1:
This model is intended for use on a 230V circuit and
has a grounded outlet that matches the machine’s
electrical cord plug, as shown in Figure 8-1. Make
sure the tool is connected to an outlet having the
same configuration as the plug. No adapter is
available or should be used with this machine. If the
machine must be reconnected for use on a different
type of electric circuit, the reconnection should be
made by qualified electrician. After reconnection,
the machine should comply with all local codes and
ordinances.
Make sure the voltage of your power supply
matches the specifications on the motor plate of the
machine.
Figure 8-1
8.3 Extension Cords
The use of extension cords is discouraged. If
possible, position your machine within reach of the
power supply. If an extension cord becomes
necessary, use only 3-wire extension cords that
have 3-prong grounding plugs and 3-pole
receptacles that accept the tool's plug. Make sure
the cord rating is suitable for the amperage listed on
the machine’s motor plate. An undersized cord will
cause a drop in line voltage resulting in loss of
power and overheating.
Do not use a damaged or worn extension cord.
Repair or replace before use.
Use Table 1 as a general guide in choosing the
correct size cord. If in doubt, use the next heavier
gauge. The smaller the gauge number, the heavier
the cord.
Recommended Gauges (AWG) of Extension Cords
Amp Rating
Volts
Total length of cord in feet
More
Than
Not
More
Than
120
240
25
50
50
100
100
200
150
300
AWG
0
6
18
16
16
14
6
10
18
16
14
12
10
12
16
16
14
12
12
16
14
12