JANDY Levolor K-2000 handleiding

20 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 8 van 20
3.3 Changing Wiring for 110 Volt
Operation
WARNING
PotentiallyhighvoltagesintheLevolor
controlbox
cancreatedangerouselectricalhazards,possibly
causingdeath,seriousinjuryorpropertydamage.
Turnoffpoweratthemaincircuitbreakerproviding
powertothecontrolboxtodisconnectthecontrol
boxfromthesystem.Toproperlyandsafelywirethe
system,besuretocarefullyfollowtheapplicable
requirementsoftheNationalElectricalCode(NEC),
NFPA70ortheCanadianElectricalCode(CEC),
CSAC22.1.Allapplicablelocalinstallationcodes
mustalsobeadheredto.
Refer to Figures 3 and 4 and do the following:
1. Cut the splice cap connecting the black/white and
the black/red wires. See Figure 3.
2. Connect the black/red wire with the black wire and
connect to the line side of power. See Figure 4.
3. Connect the black/white wire with the black/
yellow wire and connect to the neutral side of
power. See Figure 4.
3.4 Grounding
Connect the green ground wire marked to the
grounding terminal of your electrical service or supply
panel with a continuous copper conductor having green
insulation. It must be equivalent in size to the circuit
conductors supplying this equipment, but no smaller
than No. 12 AWG (3.3mm). Refer to your local codes
for the acceptable grounding wire gauge.
BLK/RED
BLK
Green
Transformer
1
2
5
6
Ground
Line
Neutral
BLK/WHT
BLK/YEL
Figure4.ModiedWiringfor110VoltOperation
Page 8
ENGLISH
Jandy Pro Series Levolor
®
II Electronic Water Leveler
Models K-2000
|
Installation and Operation Manual

Bekijk gratis de handleiding van JANDY Levolor K-2000, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkJANDY
ModelLevolor K-2000
CategorieNiet gecategoriseerd
TaalNederlands
Grootte2855 MB